Product description:
Frequently Asked Questions
What is the KMA 802/822 used for?
The KMA 802/822 is a continuous measurement system used to test and adjust diesel injection pumps with up to 12 cylinders. It measures the injected fuel volume accurately and is used in conjunction with an injection pump test stand.
What are the key differences between KMA and glass measurement techniques?
The KMA measurement technique continuously measures the injected fuel volume, eliminating the need for a correction factor for residual oil in the measuring glass. The glass technique, on the other hand, measures the volume in a glass and may have residual oil, leading to potential measurement differences.
How does the KMA system handle temperature differences?
The KMA system delivers the test oil to the measurement system much faster than the glass technique, which can result in different temperatures at the time of measurement. The system accounts for this temperature difference using the computer to ensure accurate results comparable to the glass technique.
What are the components included in the KMA 802/822 package?
The package includes a PC with software, a monitor, a printer, connection cables, and various adapters. It also includes a hydraulic system with damping units and quick-connect fittings for connecting to test nozzles.
How do you install the PC unit on the test stand?
To install the PC unit, remove the rear panel of the protective housing, secure the housing to the EPS control panel using four M6 screws, and insert the PC from the back. Ensure the PC is positioned correctly on the left side of the housing.
How do you mount the control and display unit?
The control and display unit, including the monitor and keyboard, is mounted on the EPS cover. The monitor and keyboard are adjustable and can be swiveled for optimal viewing and operation. Use Velcro straps to secure the keyboard and monitor in place.
What are the steps to connect the cables?
Connect the cables as described in section 4.4, ensuring they are properly secured with cable ties. For the KMA 802/822, the cables should be installed and fixed on the back of the test stand, and the lower rear panel should be reattached after installation.
What are the maintenance requirements for the KMA 802/822?
Regular maintenance includes cleaning the measurement system, checking for leaks, and replacing worn parts. The system should be inspected periodically for wear and tear, and the components should be cleaned and maintained according to the specified intervals.
How do you handle contamination of the measurement system?
To prevent contamination, ensure that the measurement system is cleaned regularly. Use the provided cleaning tools to remove any residue or debris, and ensure that the system is properly sealed to prevent ingress of foreign substances.
What are the technical specifications of the KMA 802/822?
The KMA 802/822 meets the electromagnetic compatibility (EMC) requirements of the 2004/108/EC directive. It is classified as category C2 according to EN 61 800 and may cause high-frequency interference in residential areas, requiring mitigation measures.
Related products from Bosch
OTS
User manual 4 pages
HCP 0006 A
User manual 24 pages
BL 200
User manual 16 pages
FAA-420-RI-DIN
User manual 8 pages
FAA-420-RI-DIN
User manual 8 pages
HBE 0012 A
User manual 24 pages
HBC 0010 A
User manual 24 pages
DMF 10 Zoom PROFESSIONAL
User manual 199 pages
D-tect 150 SV
User manual 219 pages
D-tect 150 SV
User manual 240 pages
D-tect 150 SV
User manual 252 pages
DLE 50 PROFESSIONAL
User manual 208 pages
BEA 070
User manual 40 pages
BEA 070
User manual 52 pages
BEA 070
User manual 64 pages
BEA 070
User manual 268 pages
FWA 4630
User manual 32 pages
FWA 4630
User manual 32 pages
ARD-AYZ12
User manual 44 pages
GAM220MF Professional
User manual 62 pages