Product description:
Frequently Asked Questions
How to power up the PosiTector 200?
Press the center navigation button to power up the gage. The gage will automatically go to sleep after 5 minutes of inactivity and completely power off after 4 hours of inactivity.
How to zero the probe?
To zero the probe, follow the steps on page 5 of the manual. Ensure the probe is clean and at ambient temperature before zeroing, especially for rough surfaces or extreme temperatures.
What is the purpose of couplant?
Couplant is required to propagate ultrasound into the coating. Use water for smooth coatings or glycol gel for rougher surfaces. Test the surface with a small amount of couplant to avoid staining.
How to measure coating thickness?
Remove the protective rubber cap from the probe, power up the gage, apply couplant, place the probe flat on the surface, and press down. Lift the probe when you hear a double beep or leave it in place for continuous measurements.
How to verify accuracy of the gage?
Verify accuracy at the beginning and end of each shift, or if the gage is dropped or suspected of giving incorrect readings. Use known reference standards such as included plastic shims or test blocks for verification.
How to adjust the measuring range?
To adjust the measuring range, select the Set Range option in the menu and use the navigation buttons to increase or decrease the displayed value. Ensure the range is set appropriately for the coating thickness being measured.
What is the default measuring range for the PosiTector 200?
The default measuring range for most probes is set to cover typical coating thicknesses. For example, the B probe has a range of 13 to 1000 microns (0.5 to 40 mils), while the C probe ranges from 50 to 3800 microns (2 to 150 mils).
How to calibrate the PosiTector 200?
Calibration is a controlled process performed by the manufacturer or a certified lab to ensure the gage reads within the stated accuracy. Calibration involves measuring traceable standards and verifying results against known values.
What is Max Thick Mode and how does it work?
Max Thick Mode is a setting that allows the gage to measure the thickness associated with the highest peak in the ultrasonic waveform. This mode is useful for multi-layer coatings and can be enabled through the menu settings.
How to save calibration adjustments?
To save calibration adjustments, select the Thickness menu option, adjust the displayed measurement value to match the known thickness of the sample, and use the OK button to save the changes. For advanced models, use the navigation buttons to select and adjust multiple layers.
Related products from DeFelsko
PosiTector 6000
User manual 45 pages
PosiTector 6000
User manual 48 pages
PosiTector 6000
User manual 61 pages
PosiTector 6000
User manual 64 pages
PosiTector 6000
User manual 38 pages
PosiTector DPM
User manual 38 pages
PosiTector DPM
User manual 40 pages
PosiTector DPM
User manual 60 pages
PosiTector DPM
User manual 65 pages
PosiTector SPG
User manual 38 pages
PosiTector SPG
User manual 52 pages
PosiTector SPG
User manual 37 pages
PosiTector BHI
User manual 62 pages
PosiTector GLS
User manual 16 pages
PosiTector GLS
User manual 57 pages
PosiTector SHD
User manual 48 pages
PosiTector SHD
User manual 57 pages
PosiTector UTG
User manual 53 pages
PosiTector UTG
User manual 77 pages
PosiTector RTR
User manual 54 pages