Product description:

The Dickson KT856 is a high-precision measuring instrument designed for accurate temperature measurement. It features a durable construction and a clear digital display for easy reading. The device is suitable for use in various environments, including industrial, laboratory, and field applications. It offers reliable performance and consistent results, making it a valuable tool for professionals who require precise temperature monitoring.

Frequently Asked Questions

What is the temperature range for KT800 models?

The KT800 model supports a temperature range of 0 to +100°F/C, -50 to +50°F/C, and 0 to +250°F/C. It does not support high-temperature monitoring beyond these ranges.

What is the maximum operating temperature for KT804?

The KT804 model can operate up to a maximum of +2100°F (1177°C) with its 6-inch high-temperature K-Thermocouple probe and Teflon-coated cable.

What is the temperature accuracy for these recorders?

The temperature accuracy across all models is ±1.8°F (±1°C), ensuring reliable readings under normal operating conditions.

How long does a battery last in 7-day recording mode?

In 7-day recording mode, the battery life of KT800 models lasts approximately two days. For longer periods like 31 days, additional power sources or extended batteries may be required.

What are the ambient operating conditions for these recorders?

The recorder operates within an ambient temperature range of +32 to +122°F (0 to +50°C) and humidity levels up to 95% RH, provided that condensation is not present.

How do you adjust the chart time manually?

To adjust the chart time manually, insert a coin into the groove of the chart hub and turn it clockwise until the correct hour (and day if applicable) aligns with the timing arrow on the dial.

What is the purpose of the Dip Switch Set-up feature?

The Dip Switch Set-up allows users to configure recording time options, temperature ranges, and other operational settings. It ensures that the recorder functions according to specific application requirements.

How do you calibrate the unit for user-defined measurements?

To enter calibration mode, press and hold both the On/Off button and Adjust-Down button until the LED blinks green. Use the adjustment buttons to set desired units (Fahrenheit or Celsius) and store settings in memory.

What is the recommended frequency for recalibrating these instruments?

It is recommended to recalibrate your instrument every 6 to 12 months, depending on usage conditions. More frequent calibration may be needed if the unit operates in extreme environments or experiences heavy use.

How do you adjust pen positions during setup?

During pen adjustment, press and hold both Pen Home and On/Off buttons until the LED blinks green. Use Adjust-Up and Adjust-Down to move pens to their correct maximum temperature lines on the chart before confirming with the Pen Home button.