Flex ADL 30 (186 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the laser class of the ADL 30/60/120?
The ADL 30/60/120 is a Class 2 laser device, compliant with IEC 60825-1:2007. It has a maximum output power of ≤1 mW and operates within a wavelength range of 635–665 nm. The laser beam is designed for safe use when following the provided safety guidelines.
How to turn the device on and off?
To turn the device on, press and hold the power button for approximately 3 seconds. The device will briefly display the ambient temperature in °C. To turn it off, press and hold the power button for the same duration.
What are the technical specifications of the ADL 30/60/120?
The ADL 30/60/120 has a digital display, a laser diode with a wavelength of 635–665 nm, and a laser class of 2. It has an accuracy of ±0.05° for 0°/90° and ±0.1° for angles between 0° and 90°. The device is powered by 2 x LR03/AAA batteries and has a battery life of approximately 10 hours.
How to check the measurement accuracy?
To check the measurement accuracy, ensure the device is placed on a flat surface (~0°) for angles up to 45°, or on a vertical surface (~90°) for angles over 45°. Follow the detailed steps provided in the manual to verify the accuracy and calibrate if necessary.
How to calibrate the device?
To calibrate the device, place the base on a flat surface, press and hold the REF button until 'CAL 1' appears, then rotate the device 180° and press the REF button again until 'CAL 2' appears. A signal tone confirms the calibration. Ensure the device shows the same readings in both positions for proper calibration.
What are the safety precautions for using the device?
Never point the laser beam at people or animals, and avoid looking directly into the laser. Use the device only in safe environments, away from flammable materials. Ensure the device is not used in explosive atmospheres. Always follow the safety instructions provided in the manual to prevent injury or damage.
How to replace the batteries?
To replace the batteries, locate the battery compartment and remove the old batteries. Insert new LR03/AAA batteries, ensuring the correct polarity. Replace the battery compartment cover and ensure the device is securely closed. Always use original batteries to maintain device performance and safety.
How to use the memory function?
To store a measurement, press the memory button. The current reading is saved in one of the nine memory slots. If a new value is stored, the previous nine readings are deleted. To recall stored values, press the memory recall button, starting with the most recent stored measurement.
What is the purpose of the reference angle function?
The reference angle function allows you to set a reference point for measuring angles. When the device is in reference mode, it will signal acoustically when the angle is set to 0°, 45°, 90°, or the last stored value. This helps ensure accurate and consistent measurements during use.
How to maintain and care for the device?
Handle the device with care, avoiding shocks, vibrations, and extreme temperatures. Clean the device using a soft, dry cloth. Store the device in its protective case when not in use. Remove batteries if the device will not be used for an extended period. Always use original replacement parts and have the device repaired by authorized service personnel to ensure safety and performance.