Frequently Asked Questions
What is the pH measurement range of the sensION™+ meter?
The sensION™+ meter measures pH within the range of –2.00 to 19.99. The resolution for pH is 0.01 pH units, and the measuring error is ≤ 0.01 pH.
What is the ORP measurement range and resolution?
The ORP (Redox) measurement range is ±1999 mV, with a resolution of 1 mV. The measuring error for ORP is ≤ 1 mV.
What are the DO measurement ranges and resolutions?
The dissolved oxygen (DO) measurement ranges are 0.00 to 19.99 mg/L and 20.0 to 22.0 mg/L (at 25°C). The resolution for DO is 0.01 mg/L or 0.1% (depending on the range).
What is the conductivity measurement range and resolution?
The conductivity measurement range is 0.01 to 500 mS/cm, with auto-ranging. The resolution varies with the range, and the measuring error is ≤ 0.5% of the measured value.
What is the temperature measurement range and resolution?
The temperature measurement range is 0 to 50 °C (32 to 122 °F), with a resolution of 0.1 °C (0.1 °F). The measuring error is ≤ 0.2 °C (≤ 0.4 °F).
What are the battery requirements for the meter?
The meter operates on three AA alkaline or rechargeable NiMH batteries. Battery life is over 500 hours, and the meter automatically powers off after 5 minutes of inactivity.
What is the IP rating of the meter enclosure?
The meter enclosure has an IP67 rating, which means it is dust-tight and can withstand immersion in water up to 1 meter for 30 minutes.
What are the dimensions and weight of the meter?
The dimensions of the meter are 18.6 x 7.3 x 3.8 cm (7.32 x 2.87 x 1.5 in.), and the weight is 300 g (0.66 lb).
What are the operating and storage temperature ranges?
The operating temperature range is 0 to 50 °C (32 to 120 °F), and the storage temperature range is –15 to +65 °C (5 to +149 °F).
How does the meter handle TDS conversion?
The meter uses a TDS conversion factor, which can be set between 0.00 to 4.44 (default is 0.64). This factor is used to convert conductivity measurements to TDS values.
Related products from Hach
DR 3900
User manual 403 pages
DR 3900
User manual 446 pages
DR 3900
User manual 15 pages
LANGE DR 1900
User manual 206 pages
2100Q
User manual 306 pages
2100Q
User manual 344 pages
LANGE 2100Qis
User manual 206 pages
LANGE 2100Qis
User manual 306 pages
LANGE 2100Qis
User manual 344 pages
BOD Direct plus
User manual 290 pages
LANGE LUMIStox 300
User manual 45 pages
H-Series
User manual 136 pages
H260G
User manual 136 pages
H270GB
User manual 136 pages
H280G
User manual 136 pages
9245
User manual 162 pages
DR300
User manual 172 pages
9525sc
User manual 226 pages
ORBISPHERE 3658
User manual 284 pages
Polymetron 9610sc
User manual 382 pages