Product description:

The Haug STATIC CONTROL is a measuring instrument designed for the detection and measurement of static electricity. It provides accurate readings of static voltage levels in various environments. The device is suitable for industrial and laboratory applications where monitoring electrostatic charge is essential. It features a reliable and durable construction, ensuring consistent performance under different conditions. The instrument is easy to operate and offers clear display of measured values.

Frequently Asked Questions

What does the Haug STATIC CONTROL measure?

The Haug STATIC CONTROL detects and quantifies electrostatic charge, surface potential and related field strength on objects and materials. It provides clear measurement information to help evaluate electrostatic risk, optimize mitigation measures, and reduce product contamination in industrial production environments. For best results, take multiple readings and average them when assessing large surfaces.

How does the instrument detect electrostatic charge?

The device uses high-impedance sensors and field-sensing electrodes to measure electrostatic potential and field gradients without contacting the surface. This non-contact measurement method preserves delicate surfaces and prevents disturbing the charge distribution, allowing accurate characterization and safer handling of sensitive components in production and test setups.

What accuracy and resolution can I expect from this device?

Accuracy and resolution depend on the specific Haug STATIC CONTROL model and sensor configuration, but the instrument is designed for precise, repeatable readings suitable for industrial control. Expect stable, low-noise measurements when operated under recommended conditions; regular zero checks and routine calibration will maintain traceable accuracy and reliable long-term performance.

In which environments and applications can I use the STATIC CONTROL?

The STATIC CONTROL is suitable for manufacturing lines, cleanrooms, ESD-protected areas, and quality labs where electrostatic monitoring is needed. Typical applications include electronic assembly, coating processes, printing, and material handling. Use it in controlled ambient conditions for optimal results and avoid direct exposure to heavy condensation or corrosive atmospheres.

How is the instrument powered and how does it connect to other systems?

Haug STATIC CONTROL units are typically powered by rechargeable batteries or mains adapters and offer digital interfaces such as USB, serial, or industrial I/O for data transfer. These connectivity options facilitate logging, process integration, and real-time monitoring. Ensure correct grounding and compatible cable connections to maintain measurement integrity.

What maintenance and calibration are required to keep accurate readings?

Regular maintenance includes keeping sensor surfaces clean, avoiding mechanical shocks, and performing scheduled zero checks. Periodic calibration against traceable references is recommended to ensure measurement accuracy. Proper storage, avoiding humidity extremes, and following a calibration plan will extend sensor life and maintain reliable long-term performance.

Which accessories and probes are compatible with the STATIC CONTROL?

The instrument supports a range of non-contact electrodes, grounding accessories, and mounting fixtures designed for different measurement distances and object geometries. Choosing the correct probe improves sensitivity and repeatability. Use manufacturer-recommended accessories to ensure mechanical compatibility and preserve the instrument's performance characteristics.

How do I interpret the measurement readings and what units are used?

Measurements are typically reported as surface potential (volts) or field strength (volts per meter), depending on the mode. Interpreting readings requires understanding the measurement distance and sensor geometry; lower voltages indicate better electrostatic control. Combine numeric results with process thresholds to decide on mitigation actions such as grounding or ionization.

Is the STATIC CONTROL safe to use near sensitive electronics and components?

Yes, because it uses non-contact sensing and high input impedance, the STATIC CONTROL is designed to avoid disturbing sensitive electronics. Nevertheless, observe ESD-safe handling practices, ensure proper grounding of operators and equipment, and avoid exposing devices to rapid discharge events during measurement to protect both the DUT and the instrument.

How can I reduce electrostatic interference when taking measurements?

To minimize interference, perform measurements away from strong electromagnetic sources, ensure consistent measurement distance, use shielding or grounded fixtures where appropriate, and stabilize the environment by controlling humidity. Averaging repeated readings and scheduling measurements during steady process conditions will also improve reliability and reduce the influence of transient disturbances.