HT HT309 (72 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How to replace the battery?
To replace the battery, first turn off the device using the ON/OFF button. Remove the battery compartment cover and insert a new 1x9V alkaline battery (NEDA1604, JIS006P, IEC6F22). Ensure the battery is properly seated. When the battery is low, the display will show a symbol indicating the need for replacement.
How to calibrate the device?
The device is pre-calibrated to meet the technical specifications outlined in this manual. It guarantees performance for 12 months. If the device is stored for a long period in extreme environmental conditions, allow it to return to normal operating conditions before use, as specified in section 6.2.1.
How to reset the display to zero?
Press the ZERO button to automatically reset the display to zero. This is useful when positioning the sensor cover over the photodiode sensor without seeing the indication '000'. If the cover is not in place, the display will show 'CAP' and the cover should be inserted before repeating the operation.
How to select the light source type?
Press and hold the HOLD/L.S. button for more than one second to select the light source type. The display will show a flashing symbol indicating the selected source. Use the arrow buttons to choose from available sources (L0 to L9). For customizable sources (L7, L8, L9), you can adjust the correction factor using the arrow buttons.
How to measure illuminance?
To measure illuminance, place the sensor horizontally and perpendicular to the light source. Ensure the protective cover is on the sensor. Turn on the device, select the desired unit (Lux or Fc), and choose the light source type. The device will display the illuminance value with automatic scale adjustment.
How to measure light intensity?
To measure light intensity, use the formula: Light Intensity (Cd) = Illuminance (Lux/Fc) × Distance from the source (m²/ft²). Place the sensor horizontally and perpendicular to the light source. Select the unit for distance (m or ft) and input the distance value. The device will display the light intensity value with automatic scale adjustment.
How to activate the HOLD function?
Press the HOLD/L.S. button to activate the HOLD function, which freezes the displayed value. The display will show the 'HOLD' symbol. Press the same button again to exit the function. This is useful when the measured value remains constant during a measurement.
How to save measurement data?
Press the MEM/READ button to save the displayed data to internal memory. The display will show the memory location and the 'M' symbol. To recall saved data, press and hold the MEM/READ button. The display will show 'MEM' and 'R' along with the last used memory location. Use the arrow buttons to select different memory locations.
How to clear internal memory?
To clear internal memory, first turn off the device. While turning it on again, hold the MEM/READ button. The display will show 'MEM' and 'CLr' for a few seconds, and the memory location will reset to '01'. This will erase all saved data.
How to disable the Auto Power Off function?
To disable the Auto Power Off function, turn on the device, press and hold the ON/OFF button for more than one second to remove the ' ' symbol from the display. Then turn the device off and on again to enable the function. This prevents the device from turning off automatically after 5 minutes of inactivity.
Related products from HT
HT96U
User manual 8 pages
HT304k
User manual 67 pages
HT305
User manual 67 pages
SOLAR03
User manual 120 pages
SOLAR03
User manual 123 pages
HT8051
User manual 74 pages
GEO416
User manual 116 pages
HT4010
User manual 76 pages
HT4012
User manual 84 pages
EQUITEST
User manual 96 pages
HT7
User manual 100 pages
IRONMETER
User manual 104 pages
MPP300
User manual 114 pages
64
User manual 164 pages