IME Nemo D4-Le (96 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How to set up the custom display page?
To set up the custom display page, navigate to the 'Pagina visualizzazione personalizzata' section. Select the desired measurements for each of the three display lines from the available options. Once configured, this page will become the default display upon device startup.
What are the available connection types?
The device supports various connection types including single-phase (1N1E), three-phase three-wire balanced (3-1E), three-phase four-wire balanced (3N1E), three-phase three-wire unbalanced (3-2E), and three-phase four-wire unbalanced (3N3E). Each connection type has a specific wiring diagram.
How to configure the display brightness?
The display brightness can be set to four levels: 0%, 35%, 70%, or 100%. Adjust the brightness level using the settings menu under 'Illuminazione display' to control the percentage of illumination.
What are the available integration times for current and average power?
The integration time for current and average power can be set to 5, 8, 10, 15, 20, 30, or 60 minutes. The selected time applies to both current and average power measurements.
How to start the energy counter with voltage or power?
To start the energy counter, select either voltage or power as the trigger. Voltage-based start activates when the phase voltage exceeds 20V. Power-based start uses the total active power, which can be programmed between 0.1% and 50% of the nominal power.
What communication protocols are supported?
The device supports RS485 communication with Modbus RTU/TCP or BACNET protocols. These options are available depending on the model. Configure the communication settings under the respective sections for Modbus or BACNET.
How to configure the relay output function?
The relay output can be configured for energy pulses, alarm, or remote state switching. Choose the desired function under 'Funzione uscita relè'. For energy pulses, set the pulse weight and duration. For alarms, define the threshold, type (minimum or maximum), and contact type (normally open or closed).
What are the available relay switching modes?
The relay can be configured in bistable (rMtb) or timed (rMtt) modes. In bistable mode, the relay switches based on remote commands with specified on and off delays. In timed mode, the relay switches after a set delay following activation.
How to set up the energy meter for different power modes?
The energy meter can be set to four modes: synchronous, asynchronous, tariff-based, or pulse-based. Synchronous mode uses two digital inputs, asynchronous mode is always active, tariff-based mode allows for multiple tariff registers, and pulse-based mode counts pulses from digital inputs.
How to configure external TA and TV ratios?
The external TA and TV ratios can be set to adjust the energy measurements. The TA ratio (Ct) can be set from 1 to 9999, and the TV ratio (Vt) from 1.00 to 10.00. Changing these ratios will automatically reset the energy counters.
Related products from IME
CONTO D4-Pt
User manual 38 pages
CONTO D4-Pt
User manual 27 pages
Nemo 96HD
User manual 14 pages
Nemo 96HD
User manual 15 pages
Nemo D4-Dc
User manual 8 pages
Nemo D4-Dc
User manual 52 pages
Nemo D4-e
User manual 48 pages
Nemo D4-e
User manual 60 pages
Nemo 96HDLe
User manual 19 pages
CONTO D4-Pd
User manual 23 pages
CONTO D4-Pd
User manual 40 pages
CONTO D4-Pd
User manual 36 pages
CONTO D4-Pd
User manual 36 pages
CONTO D4-Pd
User manual 35 pages
CONTO D4-Pd
User manual 32 pages
CONTO D4-Pd
User manual 8 pages
CE4DMID32
User manual 14 pages
Conto D4-Pd MID
User manual 14 pages
CONTO D2-Pd
User manual 32 pages
CE4DT06A2
User manual 40 pages