Keysight U1401B (114 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How do I charge the batteries in the U1401B?
To charge the batteries, set the slide switch to CHARGE, connect the AC adapter, and use the specified 24 V AC adapter. A red light indicates charging, and a green light shows full charge. Always use the recommended battery type and avoid shorting or reverse polarity.
What safety precautions should I take when using the U1401B?
Ensure correct terminal connections before measurements to avoid damage. Do not exceed input limits. Avoid discharging batteries by shorting or reverse polarity. Never turn the rotary switch while charging, as a 24 V DC supply is applied to the charging terminal.
How do I measure AC voltage with the U1401B?
Set the rotary switch to V or mV, connect the test leads to the INPUT terminals, and probe the test points. Press the button to display dual measurements. Ensure the meter is properly calibrated and the test leads are securely connected.
How do I measure DC voltage with the U1401B?
Set the rotary switch to V or mV, connect the test leads to the INPUT terminals, and probe the test points. Press the button to display dual measurements. Always ensure the circuit is disconnected from power before taking measurements.
How do I measure AC current with the U1401B?
Set the rotary switch to mA, connect the test leads to the INPUT terminals, and probe the circuit in series. The meter will display the current value. Ensure the circuit is de-energized before connecting the meter to avoid damage.
How do I measure resistance and perform a continuity test?
Set the rotary switch to the resistance range, connect the test leads to the INPUT terminals, and probe the resistor or shunt. For continuity test, press the button to toggle the audible function. The meter will beep if resistance is below the specified threshold.
How do I measure temperature with the U1401B?
Set the slide switch to M to disable output, set the rotary switch to mV, and press the button for more than one second. Connect the thermocouple probe to the INPUT terminals and touch the surface to be measured. Ensure the probe is securely in contact and the surface is clean.
What is the overload protection for the input terminals?
The input terminals have overload protection limits: 250 Vrms for AC/DC voltage measurements and 250 V/630 mA with a fast-acting fuse for resistance, continuity, temperature, and current measurements. Always ensure the input voltage and current do not exceed these limits.
How do I use the frequency measurement function?
During AC/DC voltage or current measurements, press the button to measure the signal frequency at any time. This function is available during voltage or current measurements and provides the frequency of the detected signal.
What should I do if the low battery warning appears?
Charge the batteries immediately when the low battery annunciator starts flashing. A new battery may require three to four charge/discharge cycles to reach full capacity. If the meter indicates charging is complete after ten minutes, this is normal for rechargeable batteries. Remove and reinsert the battery if needed.