Product description:

The MaxFLO2 is a high-precision measuring instrument designed for accurate flow measurement in various industrial applications. It features a robust construction suitable for harsh environments and offers reliable performance under different operating conditions. The device supports multiple measurement units and provides clear digital readouts for easy interpretation of results. Its compact design allows for easy integration into existing systems, and it is equipped with a user-friendly interface for straightforward operation. The MaxFLO2 is ideal for use in process control, water treatment, and other fields where precise flow monitoring is essential.

Frequently Asked Questions

What is the MaxFLO2 used for?

The MaxFLO2 is a compact air/oxygen gas mixing device designed to provide intermittent or continuous controlled flows of an air/oxygen gas mixture to infant, pediatric, and adult patients. It is intended for use with a Maxtec Oxygen Analyzer as a spot checking device in institutional environments.

What are the contraindications for using the MaxFLO2?

The MaxFLO2 is not intended for use as a life support device. It should only be used with oxygen and medical air, and under the supervision of a healthcare professional. It must not be used near open flames or in MRI environments.

What are the operational requirements for the MaxFLO2?

The MaxFLO2 requires clean, dry, medical grade oxygen and air at a line pressure of 50 ± 5 PSIG (345 ± 35 kPaG). The gas sources must be connected to the respective inlet fittings, and the device must be mounted vertically for correct function.

How do you set the flow and oxygen concentration on the MaxFLO2?

To set the flow and oxygen concentration, use the flow control knobs to adjust the air and oxygen flowmeters. Refer to Table 1 in the manual to determine the appropriate flow rates for the desired FiO2. The float ball on each flowmeter indicates the flow rate when read at the centerline.

What is the purpose of the mixed gas analysis port?

The mixed gas analysis port allows for spot checking or monitoring of oxygen concentrations being delivered. It contains a spring-loaded valve that opens when a flow diverter is connected to an analyzer/monitor. The valve automatically closes when the diverter is removed.

What are the recommended cleaning procedures for the MaxFLO2?

Clean the MaxFLO2 as recommended in section 5 of the manual. Avoid using cleaning agents containing phenols, ammonia chloride, or chloride compounds. Excessive cleaning can cause residue buildup on critical components, affecting performance.

What are the warranty terms for the MaxFLO2?

Maxtec warrants the MaxFLO2 to be free from defects in workmanship or materials for 3 years from the date of shipment, provided it is used and maintained according to the instructions. The warranty covers replacements, repairs, or credit for defective equipment, but excludes routine maintenance and abuse.

How should the MaxFLO2 be installed on an IV pole?

Connect the 22mm Male/15mm Female conical outlet fitting to the male DISS fitting on the bottom of the device. Mount the unit securely using the pole clamp, ensuring the pole sits in the curved groove of the clamp’s arm. Tighten the screw clockwise until the unit is completely secure.

What are the flow characteristics of the MaxFLO2?

The MaxFLO2 has a maximum total flow of 10 LPM at 21% O2 or 100% O2, and 20 LPM at 60% O2. Back pressure can affect low flow performance, so ensure the device is used in an environment with appropriate pressure conditions.

What are the safety precautions for using the MaxFLO2?

The MaxFLO2 should not be used near open flames or in MRI environments. It must only be used with medical grade oxygen and air, and under the supervision of a healthcare professional. Ensure the mixed gas analysis port is clean and free of foreign matter before each use.