Milwaukee MA871 (126 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How do I calibrate the MA871 refractometer?
Calibration should be performed daily, before measurements, after battery replacement, or between long measurement series. Press the ON/OFF key, then release to display test screens. Fill the sample well with distilled or deionized water, and ensure it is covered from intense light during calibration.
What is the measurement range of the MA871?
The MA871 measures sucrose concentration from 0 to 85% Brix. It also operates within a temperature range of 0 to 80 °C (32 to 175 °F) with automatic temperature compensation between 10 and 40 °C (50 to 104 °F).
How accurate is the MA871 refractometer?
The MA871 has an accuracy of ±0.2% for Brix measurements and ±0.3 °C (±0.5 °F) for temperature readings. These specifications ensure reliable and consistent results for sucrose concentration in aqueous solutions.
What is the purpose of the dual-level display?
The dual-level display shows the Brix measurement on the primary screen and the temperature on the secondary screen. It also displays icons for low battery status and other helpful messages to guide the user during operation.
How does the MA871 handle temperature compensation?
The MA871 automatically compensates for temperature variations between 10 and 40 °C (50 to 104 °F). This ensures accurate Brix measurements by adjusting for the effect of temperature on refractive index.
What should I do if the instrument is damaged during shipping?
If the instrument shows any signs of damage upon arrival, notify your dealer immediately. The instrument should be examined carefully before use, and any damage must be reported to ensure proper handling and resolution.
How long does the battery last on the MA871?
The MA871 uses 1 x 9-volt battery and can perform up to 5000 readings. A low battery indicator is displayed, and the instrument automatically turns off after 3 minutes of non-use to conserve power.
What is the minimum sample volume required for measurement?
The minimum sample volume required is 100 µL, which covers the prism completely. Ensure the sample is clean and free from particulate matter to avoid damaging the prism and obtaining accurate results.
Can I use metallic tools to transfer samples?
No, metallic tools such as needles, spoons, or tweezers should not be used to transfer samples. These can scratch the prism. Use plastic pipettes instead to avoid damage and ensure accurate measurements.
What should I do if the instrument shows an error message?
Error messages on the MA871 indicate issues such as temperature out of range, low battery, or incorrect calibration. Refer to the error message guide in the manual to troubleshoot and resolve the issue before proceeding with measurements.
Related products from Milwaukee
MW402
User manual 44 pages
MW600
User manual 62 pages
2236-40
User manual 15 pages
LDM50
User manual 253 pages
LED TAPE MEASURE
User manual 39 pages
MI414
User manual 46 pages
MI413
User manual 47 pages
MI412
User manual 49 pages
MI405
User manual 50 pages
4933385110
User manual 61 pages
4933385100
User manual 61 pages
MW150 MAX
User manual 307 pages
MW170 MAX
User manual 322 pages
MW106 MAX
User manual 374 pages
MW306 MAX
User manual 409 pages
MW180 MAX
User manual 487 pages
MW805 MAX
User manual 492 pages