Product description:

The Nuvoair AIR NEXT is a measuring instrument designed for precise air quality analysis. It features advanced sensor technology for accurate detection of various air pollutants. The device is compact and user-friendly, making it suitable for both professional and personal use. It provides real-time data and can be connected to a mobile application for extended monitoring and data analysis. The AIR NEXT is ideal for indoor and outdoor environments, offering reliable and consistent performance under different conditions.

Frequently Asked Questions

How do you set up the Air Next device?

To set up your Air Next device, download the NuvoAir app from the AppStore or Google Play Store. Create an account or sign in to an existing one. Select your profile if you are using the Air MD version. Enable Bluetooth on your mobile device and follow the on-screen instructions to connect the device.

How do you perform a lung function test with Air Next?

To perform a lung function test, insert a new turbine by sliding it through the device. Turn the turbine clockwise until it locks into place. Enable Bluetooth on your mobile device and allow the app to access Bluetooth. Tap the plus button to start the test. The spirometer lights up when connected. Exhale into the mouthpiece as hard and fast as possible, ensuring your exhalation exceeds 6 seconds for a high-quality test.

What are the requirements for a valid lung function test?

A valid lung function test requires the user to exhale for at least 6 seconds, take a slow deep breath, and blow as hard and fast as possible into the mouthpiece. The user should rest for 15 to 30 seconds before starting a new test. Perform a minimum of 3 tests to ensure accurate results, and the app will display the best result.

What are the technical specifications of Air Next?

Air Next measures FEV1 and FVC during a forced expiratory maneuver. It connects via Bluetooth to iPhone and Android devices and is powered by 2 x 1.5 V AAA alkaline batteries. It is designed to work with disposable NuvoAir turbines and complies with European Safety Standards EN 60601-1 and EN 60601-1-2.

What are the limitations of using Air Next?

Air Next should only be used when the user is at rest and in good health. The results alone cannot be used for diagnosis, and interpretation must be done by a healthcare professional. The test results are only acceptable if the user can inhale and exhale completely and quickly. The device should not be used in environments with heat, cold, direct sunlight, or other external factors that may compromise results.

What safety precautions should be taken when using Air Next?

Air Next should never be used with a charging phone or connected to an AC/DC adaptor. Ensure the device is undamaged before use. It is a medical device class IIa and complies with safety standards. Avoid exposure to liquids and do not use it if the battery hatch is lost, as this voids the warranty.

How should the Air Next device be maintained?

Handle the Air Next device carefully and store it in clean, moisture-free conditions. Before use, check for dust or contamination. If cleaning is necessary, use only a damp cloth without detergents. Replace the batteries as needed and dispose of used turbines as electronic waste.

What are the indications for using Air Next?

Air Next is intended for use by healthcare professionals and trained adults to measure FEV1 and FVC in patients aged ≥5 years, >10 kg, and ≥110 cm. It is not intended for use in operating theatres or environments with inflammable substances. The device is for home use only for indicative purposes, and a healthcare professional should interpret the results.

What are the parameters measured by Air Next?

Air Next measures FEV1 (Forced Expiratory Volume in 1 second), FVC (Forced Vital Capacity), FEV1/FVC ratio, and PEF (Peak Expiratory Flow). These parameters are displayed as percent predictive values (%pred) based on ethnicity, gender, age, and height. Results should be interpreted by a healthcare professional with training in spirometry.

What should be done if the turbine is contaminated?

Each user should use a new, unused disposable NuvoAir turbine to avoid cross-contamination. If the turbine is not replaced between users, there is a high risk of infectious contamination. Always ensure the turbine is clean and free from impurities such as hair, sputum, or threads to maintain measurement accuracy.