Product description:
Frequently Asked Questions
How do I charge the Osstell IDx?
To charge the Osstell IDx, connect the power adapter to the unit using the designated port. The battery is a lithium-ion battery and should be charged for at least 3 hours before first use. A blue light indicates that charging is in progress.
How do I register the Osstell IDx?
You must register your Osstell IDx within two months of purchase, or it will be deactivated. Registration can be done through the unit itself or via the OsstellConnect.com website. The serial number is located on the back of the unit and under the software settings.
What is the ISQ value and how is it calculated?
The ISQ (Implant Stability Quotient) is a numerical value between 1 and 100 that represents the stability of an implant. It is calculated based on the resonance frequency signal from the SmartPeg, which is measured by the probe. Higher ISQ values indicate better stability.
How do I perform a measurement with the Osstell IDx?
To perform a measurement, connect the probe to the unit, turn it on, select the patient status, choose a new patient, select the implant position, attach the SmartPeg to the implant or abutment, and place the probe 3-5 mm away from the SmartPeg. The measurement is taken in both mesiodistal and buccolingual directions.
How do I interpret the ISQ results?
The ISQ value reflects the stability of the implant in different directions. A higher ISQ value indicates better stability relative to the bone, while a lower value may indicate less stability or a greater influence of bone anatomy. A stable ISQ value suggests no change in stability over time.
How do I clean and maintain the Osstell IDx?
The unit can be cleaned with a damp cloth or isopropyl alcohol solution. The probe and SmartPeg holder must be autoclaved according to the recommended sterilization method, validated for sterility assurance level (SAL), and in compliance with ISO 17665-1 and ISO 17664. Always use appropriate packaging during sterilization.
What are the technical specifications of the Osstell IDx?
The Osstell IDx is CE-marked and complies with EN 60601-1 and EN 60601-1-2 standards. It has a lithium-ion battery, dimensions of 203mm x 163mm x 72mm, and weighs 0.85kg. It operates within a temperature range of +10°C to +40°C and a relative humidity range of 30% to 75%.
How do I update the firmware on the Osstell IDx?
The firmware can be updated automatically when the unit connects to the internet or manually by downloading the latest version from OsstellConnect.com and inserting the USB stick into the unit while it is on. Follow the on-screen instructions to complete the update.
How do I back up data from the Osstell IDx?
To back up data, go to the Settings menu and select 'Export' to create a backup. To import an existing backup, select 'Import'. Data can also be backed up to a USB flash drive or online via Osstell Connect.
What should I do if the Osstell IDx is not working?
If the unit is not functioning, ensure it is properly registered, the probe is correctly connected, and the battery is fully charged. If the issue persists, contact the service team or return the unit and accessories to the manufacturer for repair.