SI Analytics HandyLab 750 (128 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the HandyLab 750 used for?
The HandyLab 750 is a portable measuring device designed for determining pH values. It is suitable for various applications where pH measurement is required, and it supports multiple sensor types for accurate readings.
How long does the battery last on the HandyLab 750?
The HandyLab 750 can operate for more than 1000 hours when using four Mignon batteries. The battery life may vary depending on usage and environmental conditions, and the device displays battery status through icons.
What safety precautions should be taken when using the HandyLab 750?
The device must be turned off and secured against unintended operation if there is a risk of unsafe use. This includes visible damage, electrical failure, or exposure to high temperatures. Always follow proper handling procedures and avoid opening the device unless instructed.
Can the HandyLab 750 be used in explosive environments?
The HandyLab 750 is not suitable for use in explosive environments. The HandyLab 750 EX is the model designed for such areas, and it requires specific safety measures, including the use of approved batteries and avoiding any modifications to the device.
What types of batteries are compatible with the HandyLab 750 EX?
The HandyLab 750 EX requires specific batteries rated for use in explosive environments. Approved battery types include Duracell MN1500, Energizer E91, Power One 4106, and Panasonic Pro Power LR6, all meeting temperature class requirements and operating within specified temperature ranges.
How do I connect a sensor to the HandyLab 750?
The HandyLab 750 has multiple ports for connecting various sensors. Only one sensor can be connected at a time. The device automatically detects Memosens sensors and switches to the appropriate mode. Ensure the sensor is properly connected and the polarity is correct before use.
What should I do if the battery icon shows a low charge?
If the battery icon is empty, the device may not have sufficient power for accurate measurements. Replace the batteries immediately. If the icon is partially filled, the battery still has enough capacity for limited use, but calibration may be necessary before further measurements.
How do I start a measurement on the HandyLab 750?
After connecting the sensor, press the 'on/off' or 'meas' button to power on the device. The device will perform a self-test and display calibration data before entering the measurement mode. If you press 'meas' directly, it will switch to measurement mode without the self-test.
What functions do the buttons on the HandyLab 750 perform?
The buttons on the HandyLab 750 include 'on/off' for powering the device, 'meas' for starting measurements or activating the data logger, 'cal' for initiating calibration, 'set' for accessing settings or confirming actions, 'clock' for viewing and setting the time and date, 'RCL' for displaying stored values, and 'STO' for saving measurements.
What should I do if the device shows an error message?
An error message on the device indicates a potential issue with the sensor, battery, or measurement setup. Check the sensor connection, battery status, and calibration settings. If the problem persists, refer to the troubleshooting section or contact technical support for further assistance.