Frequently Asked Questions
How to turn the detector on and off?
To turn the detector on, press the power key. To turn it off, press and hold the power key for at least 3 seconds. The detector will automatically power off after 10 minutes of inactivity to conserve battery.
How to adjust the LCD illumination?
When the detector is on, press the illumination key to turn the LCD on or off. The illumination will automatically turn off after 60 seconds of inactivity or if a key is pressed.
How to change the speaker volume?
When the detector is on, press the speaker volume key to toggle between loud, soft, and mute settings. The default volume setting is loud.
How to detect the reference level?
Position the detector in the general area where the laser beam is projected. Use the bubble vial to keep the detector level. Ensure the laser reception window faces the laser source. Move the detector as indicated on the LCD to align the datum with the laser beam. An audible tone will signal detection, with different beeping patterns indicating the direction to move.
How to mount the clamp to the detector?
Align the clamp with the detector using the alignment hole and tighten the fixing screw. This allows the detector to be securely attached to a measuring rod, pole, or similar object for accurate readings.
What is the battery type and capacity?
The detector uses 2 x AAA alkaline batteries. The battery life is approximately 20 hours, and the detector will automatically power off after 10 minutes of inactivity if no laser signal is detected.
How to adjust the accuracy setting?
When the detector is on, press the high/low accuracy key to toggle between high and low accuracy settings. High accuracy is the default setting, and low accuracy is recommended for longer distances or unstable reference levels due to vibrations or heat waves.
What is the levelling accuracy of the detector?
The levelling accuracy is ≤ 1 mm for high accuracy and ≤ 2 mm for low accuracy. The bubble vial has an accuracy of 30' / 2 mm, ensuring precise alignment with the laser beam.
How to mark the reference level?
Once the reference level is detected, mark the position at the datum line. If the top of the detector was used as a marking location, ensure the measurement compensation value (distance from top to datum) is referenced for accurate results.
What is the operating temperature range?
The detector operates within a temperature range of -10°C to +50°C (-14°F to +122°F) and can be stored between -25°C to +70°C (-13°F to +158°F).
Related products from Stanley
S150
User manual 50 pages
0-77-030
User manual 104 pages
RLD400
User manual 104 pages
IntelliMeasure
User manual 112 pages
TLM65 STHT1-77032
User manual 130 pages
TLM65 STHT1-77354
User manual 130 pages
Compulevel
User manual 132 pages
FMHT77165
User manual 134 pages
FMHT77165
User manual 134 pages
FMHT77165-0
User manual 134 pages
STHT1-77366
User manual 206 pages
STHT1-77366
User manual 206 pages
SML
User manual 208 pages