Product description:
Frequently Asked Questions
What is the measurement range of the DM70?
The DM70 measures dew point temperature accurately within the range of −60 °C to +60 °C (−76 °F to +140 °F), depending on the probe model. It can also measure other parameters such as relative humidity, temperature, and absolute humidity.
What are the main components of the DM70?
The DM70 consists of two main units: the MI70 indicator and the DMP74 probe. It can also be used with an optional sampling cell DSC74 for measuring process dew point. The MI70 indicator is a portable tool for viewing measurements, recording data, and configuring settings.
What parameters does the DM70 measure?
The DM70 measures several parameters including relative humidity (RH), temperature (T), dew point/frost point temperature (Td/f), absolute humidity (a), mixing ratio (x), and water concentration (H2O). These are displayed in both metric and non-metric units.
What are the recommendations for measuring in dry environments?
When measuring in very dry environments, ensure the environment is clean to avoid contamination. Minimize the number of connections to prevent leaks. Use an adequate flow rate and avoid dead ends. Ensure the sample tubing is as short as possible and use materials that prevent moisture diffusion.
What is the purpose of the MI70 indicator?
The MI70 indicator is a portable tool used to view measurements, record data, and configure settings for connected Vaisala instruments. It can be used with a wide range of Vaisala instruments and is part of product packages like DM70, GM70, HM70, and MM70.
What are the functions of the MI70 indicator buttons?
The MI70 indicator has shortcut buttons that change functions based on the current operation. Arrow buttons are used to navigate menus, enter sub-menus, return to previous levels, and power on/off. The charger socket and ports allow connection to probes and instruments.
What do the status icons on the MI70 display indicate?
The status icons on the MI70 display provide information about battery status, recording, calibration reminders, analog output mode, PC connection, and alarm notifications. These icons help users monitor the device's current state and operation.
How do you install alkaline batteries in the MI70?
To install alkaline batteries, unscrew the back plate of the MI70 and insert the batteries. Note that standard alkaline batteries should not be recharged. If the MI70 was ordered with a rechargeable battery, it is already pre-charged and ready for use.
What should be done if the MI70 battery cannot be charged?
If the MI70 battery cannot be charged, it must be replaced. A notification will appear on the screen if the battery is not installed or if charging is not possible. Replacement batteries can be ordered from Vaisala with item code 26755.
What is the role of the sampling cell DSC74 in the DM70?
The DSC74 sampling cell is an optional component that allows the DM70 to measure dew point in process environments. It connects to the MI70 indicator and enables the device to interface with fixed Vaisala dew point transmitters for output reading.
Related products from Vaisala
HUMICAP MMT330
User manual 40 pages
HUMICAP HMT120
User manual 103 pages
HPP272
User manual 106 pages
HMD110
User manual 93 pages
HMS112
User manual 93 pages
HMS110
User manual 93 pages
HMW110
User manual 93 pages
HMW112
User manual 93 pages
HMD112
User manual 93 pages
Indigo80
User manual 104 pages
CARBOCAP MGP261
User manual 250 pages