WIKA CPH6200-S2 (74 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How to replace the battery?
If the battery symbol appears in the lower display, it indicates a low battery and needs replacement or recharging using the appropriate charger. If the symbol appears in the upper display, the battery is completely flat. For long storage, remove the battery to preserve its life.
What is the operating voltage for mains power?
The device requires a 10.5 to 12 V DC power supply. Avoid using higher voltages as they can damage the device. Regulated power supplies are recommended to ensure safe and trouble-free operation.
How to connect a sensor?
Only use sensors model CPT6200. Connect the sensor before turning the device on to ensure proper identification. When connecting the cable, hold the plug by the cable strain relief rather than the connector housing. Ensure the sensor housing vent is clear for accurate readings.
What are the display indicators?
The main display shows the current measured value of CH1. The lower display shows CH2 or DIF (CH1-CH2) for 2-channel versions, or min/max/hold values for 1-channel versions. The 'Logg' indicator shows if the logger function is active, and 'Tare' indicates the tare function is enabled.
How to adjust the zero point?
Zero-point adjustment is available for gauge pressure sensors. Press the 'Tare' key for about 5 seconds to perform the adjustment. Ensure the difference between the displayed value and factory calibration is less than 2% for accurate results. To revert to factory calibration, press 'Tare' for about 15 seconds.
How to configure the measuring rate?
The measuring rate can be set to 'rAtE-Slo' for standard, 'rAtE-P.dEt' for peak detection, or 'rAtE-FASt' for fast filtered measurements. These settings affect the accuracy and response time of the device and should be chosen based on the application requirements.
How to set the real-time clock?
The real-time clock can be set via the 'CLOC' menu. Ensure the clock is accurate for logging and data recording. If the device is not used for a long time, the clock must be reset after reconnecting the battery.
What is the purpose of the logger function?
The logger function allows the device to record data either as single-point values (STOR) or cyclically (CYCL) with adjustable cycle time. This is useful for monitoring pressure changes over time and storing data for later analysis.
How to activate the tare function?
Press the 'Tare' key to activate the tare function, which sets the display to zero. All subsequent measurements will be relative to this tare value. To deactivate, press 'Tare' for more than 2 seconds. Activating/deactivating tare clears the max- and min-memories.
What are the safety precautions for operation?
Ensure the device is not exposed to extreme temperatures or humidity. Avoid dropping or damaging the device. If moving from a cold to a warm environment, allow the device to adjust to ambient temperature before turning it on. Always follow the safety instructions in the manual to prevent injury or damage to the device.
Related products from WIKA
CTD9100-1100
User manual 44 pages
732.14.100
User manual 40 pages
732.14.100
User manual 60 pages
732.51.100
User manual 40 pages
732.51.100
User manual 60 pages
A2G-30
User manual 44 pages
632.50.100
User manual 44 pages
632.50.100
User manual 52 pages
632.50.100
User manual 56 pages
A2G-60
User manual 52 pages
A2G-60
User manual 44 pages
A2G-15
User manual 44 pages
A2G-15
User manual 56 pages
A2G-15
User manual 60 pages
A2G-15
User manual 64 pages
A2G-10
User manual 44 pages
A2G-10
User manual 56 pages
A2G-10
User manual 60 pages
A2G-10
User manual 64 pages
TG58SA
User manual 44 pages