WIKA CPU6000-M (80 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the operating temperature range for the CPU6000 series?
The CPU6000 series operates within an ambient temperature range of -40 °C to +123.8 °C. The accuracy for temperature measurement is ±0.5 °C.
What is the humidity range for the CPU6000 series?
The CPU6000 series can operate in a relative humidity range of 0% to 100% r.h. with an accuracy of ±5.0% r.h.
What is the atmospheric pressure range for the CPU6000 series?
The CPU6000 series can measure atmospheric pressure in the range of 550 to 1,150 mbar absolute. Optional ranges include 551 to 1,172 mbar absolute with higher accuracy.
What safety precautions are required when using the CPU6000 series?
The CPU6000 series must be used only for its intended purpose. Ensure that all safety instructions are followed, and that only qualified personnel handle the equipment. Avoid exposure to hazardous media and follow local safety regulations.
What should I do if the CPU6000 series is moved from a cold to a warm environment?
If the CPU6000 series is moved from a cold to a warm environment, condensation may form, leading to potential malfunction. Allow the instrument to acclimate until its temperature matches the ambient room temperature before resuming operation.
What are the power supply requirements for the CPU6000 series?
The power supply unit should only be operated in an ambient temperature of 0 to +40 °C with humidity up to 90% relative humidity (non-condensing). Ensure the unit is not exposed to high humidity, condensation, vibration, or extreme temperatures.
What are the calibration points for the CPU6000 series?
The CPU6000 series is calibrated at specific points: 18 °C, 23 °C, and 25 °C after a warm-up time of 120 minutes for temperature measurements. For humidity, it is calibrated at 30%, 50%, and 80% r.h. under the same warm-up conditions.
What are the key components included in the CPU6000 series?
The CPU6000 series includes three models: the CPU6000-W weather station, the CPU6000-S pressure balance sensor box, and the CPU6000-M digital multimeter. These components are used for acquiring measured value data for calibration purposes.
What is the purpose of the CPU6000 series?
The CPU6000 series is designed to acquire measured value data relevant for calibration certificates. It simplifies the generation of calibration certificates and improves the productivity and quality of the calibration process.
What should I do if the power supply unit shows visible damage?
If the power supply unit shows visible damage, do not use it. The unit should be inspected and repaired by an authorized WIKA service engineer to avoid potential hazards and ensure safe operation.
Related products from WIKA
CTD9100-1100
User manual 44 pages
732.14.100
User manual 40 pages
732.14.100
User manual 60 pages
732.51.100
User manual 40 pages
732.51.100
User manual 60 pages
A2G-30
User manual 44 pages
632.50.100
User manual 44 pages
632.50.100
User manual 52 pages
632.50.100
User manual 56 pages
A2G-60
User manual 52 pages
A2G-60
User manual 44 pages
A2G-15
User manual 44 pages
A2G-15
User manual 56 pages
A2G-15
User manual 60 pages
A2G-15
User manual 64 pages
A2G-10
User manual 44 pages
A2G-10
User manual 56 pages
A2G-10
User manual 60 pages
A2G-10
User manual 64 pages
TG58SA
User manual 44 pages