What is the Codman MICROSENSOR used for?
The Codman MICROSENSOR is used for continuous intracranial pressure monitoring in neurosurgical and critical care settings. It provides real-time pressure data to guide clinical decisions, helping detect intracranial hypertension early and enabling timely therapeutic interventions and adjustments.
How does the MICROSENSOR measure intracranial pressure?
The MICROSENSOR contains a miniature pressure transducer at its tip that converts local intracranial pressure into an electrical signal. That signal is transmitted to a bedside monitor for continuous display, allowing clinicians to observe trends and instantaneous values for patient management.
How is the MICROSENSOR implanted during neurosurgical care?
The MICROSENSOR is typically implanted through a small burr hole by a trained neurosurgeon and positioned in the intended intracranial compartment. The minimally invasive approach reduces tissue disruption, and secure fixation and sterile technique are important to optimize measurement reliability and safety.
How accurate and reliable are MICROSENSOR pressure readings?
MICROSENSOR readings deliver clinically relevant, real-time pressure values with stable performance over typical monitoring periods. While designed for low drift and high fidelity, clinicians should interpret values alongside clinical findings and perform routine checks to confirm ongoing accuracy.
How long can the MICROSENSOR remain implanted for continuous monitoring?
The MICROSENSOR is intended for extended continuous monitoring and can remain implanted for days to weeks depending on clinical need and institutional protocols. Device longevity depends on patient condition and manufacturer recommendations for safe indwelling duration.
What materials is the MICROSENSOR made of and are they biocompatible?
The device is constructed from medical‑grade, biocompatible materials chosen to minimize tissue reaction and reduce complication risk. Biocompatibility helps limit inflammation and irritation; clinicians should still monitor the implant site for signs of adverse response.
Is the MICROSENSOR compatible with MRI examinations?
MRI compatibility depends on the specific model and labeled conditions; many intracranial pressure sensors are MRI‑conditional under defined field strengths and protocols. Clinical teams should confirm device labeling and follow institutional MRI safety procedures before scanning.
How should clinicians manage infection risk with MICROSENSOR implants?
Infection risk is reduced by strict sterile insertion technique, careful wound care, secure dressings, and monitoring of the insertion site. Institutions typically follow perioperative antibiotic policies and remove the sensor promptly when monitoring is no longer necessary to minimize infection risk.
Can the MICROSENSOR integrate with bedside monitors and electronic records?
Yes, the MICROSENSOR provides electronic pressure signals compatible with standard neuromonitoring displays and can be interfaced to central monitoring systems and electronic medical records through appropriate connectors or interface modules, enabling trend analysis and documentation.
What routine checks or maintenance are required while the MICROSENSOR is in use?
Routine tasks include verifying stable signal transmission, checking connectors and monitor settings, documenting baseline zeroing and calibration status if applicable, and inspecting the wound site. Adhering to institutional protocols for alarms and daily assessments helps ensure reliable monitoring.
Related products from Codman
EDS 3
User manual 24 pages
ICP EXPRESS Cable
User manual 28 pages
ACCU-FLO
User manual 40 pages
ISOCOOL
User manual 72 pages
HAKIM
User manual 100 pages
HAKIM
User manual 112 pages
MedStream
User manual 88 pages
MedStream
User manual 132 pages
VersaTru
User manual 96 pages
VPV System
User manual 134 pages