MORIA EVOLUTION 3E (96 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How to select the operating voltage (115V or 230V)?
To select the operating voltage, ensure the console is connected to the appropriate power supply. Check the voltage settings on the console and adjust accordingly. Always verify that the selected voltage matches your country's power supply requirements.
How to change the battery?
To change the battery, first turn off the console and disconnect the power supply. Remove the old battery, dispose of it as per local regulations, and install a new battery. Ensure the battery is properly seated and the connections are secure before turning the console back on.
What is the vacuum test procedure?
To perform a vacuum test, clamp the aspiration tubing at its end. Press the test button (A8) to initiate the test. The unit will check each pump (P1, P2) and display the results. If the test passes, the LED (A3) will be ON. If not, the unit cannot be operated until the issue is resolved.
How to connect the nitrogen/air hose?
To connect the nitrogen/air hose, attach the non-copper end to the gas supply. Ensure there is no pressure in the hose before connecting it to the console. Set the pressure to the minimum value using the knurled blue knob (B1), and pressurize the system to between 4 and 6 bars (58 and 87 psi).
What are the storage conditions for the console?
The console should be stored in an environment with a temperature range of 15°C to 35°C (59°F to 95°F) and a humidity level between 45% and 75%. Ensure the console is kept dry and away from moisture to prevent damage.
How to connect the aspiration tubing?
To connect the aspiration tubing, ensure it is sterile and single-use. Attach it to the console, making sure the chamber is positioned correctly. Check for any damage or blockages in the tubing and ensure all connections are secure before use.
What is the low vacuum function used for?
The low vacuum function allows for a reduced level of suction on the eye, which is useful for certain surgical procedures. When activated, the LED (A5) will be ON, and the electrical motor can only be used for a backward pass for safety.
What should I do if the vacuum level is insufficient?
If the vacuum level is insufficient, check the integrity of the aspiration tubing and ensure it is properly connected. Verify that the internal air ducts of the suction ring are not obstructed. If the issue persists, perform a vacuum test to identify and resolve the problem.
How to dispose of the used battery?
Used batteries should be disposed of at an appropriate collection point according to local regulations. Ensure the battery is not discarded as unsorted municipal waste. Follow the guidelines set by directive 2006/66/EC for the collection, treatment, recycling, and disposal of batteries.
What is the purpose of the footswitch protection?
The footswitch is protected against powerful water jets (IP X6) and water submersion beyond 1 meter (IP X8). This ensures the footswitch remains functional and safe in environments where water exposure is possible.