Leica DMR (340 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How do you set the mains voltage for the microscope?
The microscope's mains voltage is set using the selector switch on the back of the microscope. Mechanical focus models automatically adapt to local voltage, while motor focus models require manual adjustment. Always refer to the provided instructions for external power units.
What safety precautions should be taken when handling the microscope?
Ensure the workplace is free from oil and chemical fumes. Keep lamphousings at least 10 cm away from flammable materials. Always use grounded outlets and consult a service technician for any modifications or repairs.
How many lamphousings can be installed on the microscope?
Up to four lamphousings can be installed depending on the microscope configuration. Only lamphousing 106 and the microflash can be used for transmitted light, while other configurations may require additional components like deviating mirrors.
What is the purpose of the deviating mirror?
The deviating mirror is used to redirect light paths for transmitted or incident illumination. A switchable deviating mirror allows alternating between light sources, while a non-switchable mirror is fixed in position for specific lighting setups.
How do you install a deviating mirror?
To install a deviating mirror, remove the cover using a sharp object if necessary, or loosen the four screws if a mirror is already in place. Hold the mirror with the flattened side of the lamp mount pointing downward, and adjust the switch rod mount at a 45° angle for switchable mirrors.
What tools are required for assembly?
Basic tools include a 3 mm hexagonal screwdriver, cross-tip screwdriver, adjustment key for Sénarmont compensator, pol centering key, and Allen key. These are typically included in the delivery, but replacements can be obtained from the manufacturer or a tool shop.
What is the power consumption of the microscope?
The microscope has a maximum power consumption of 160 W. It operates on mains voltage of 100–115 V/230 V, ± 10% for mechanical focus, and 90–250 V for motor focus. Always ensure the voltage is correctly set before connecting the microscope.
What are the operating conditions for the microscope?
The microscope should be used in an environment with operating temperatures between 10–36 °C and relative humidity up to 80% at 30 °C. Avoid direct sunlight and vibrations to ensure accurate measurements and photomicrography.
What should be done if the fuses keep blowing?
Repeated fuse failures may indicate incorrect mains voltage settings or internal electronic defects. Consult the manufacturer's technical service for assistance, as improper voltage or faulty components can damage the microscope.
How can the microscope be used for fluorescence imaging?
Fluorescence imaging requires specific incident light sources and filters. Ensure the microscope is equipped with the appropriate components, and follow the instructions for setting up the light path and using the filters for excitation and emission wavelengths.
Related products from Leica
ATC 2000
User manual 8 pages
ZOOM 2000
User manual 12 pages
BM E
User manual 20 pages
BM E
User manual 24 pages
CM E
User manual 24 pages
DM EP
User manual 24 pages
DM LSP
User manual 46 pages
FS M
User manual 82 pages
LMD6500
User manual 92 pages
LMD7000
User manual 92 pages
WILD M690
User manual 109 pages
DMi1
User manual 132 pages
DM3 XL
User manual 136 pages
DM2700 M
User manual 156 pages
DMLS
User manual 160 pages
DM4000 B
User manual 164 pages
DM5000 B
User manual 164 pages
DM4000 M
User manual 164 pages
DM4500 P
User manual 164 pages
DM1000
User manual 178 pages