Optika LAB-30 (72 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How do I adjust the interpupillary distance?
Hold the right and left parts of the observation head with both hands and adjust the interpupillary distance by turning the two parts until one circle of light can be seen. If two circles appear, the interpupillary distance is too big, and if two overlapped circles appear, the interpupillary distance is too small.
How do I focus the microscope?
Rotate the focusing knob to bring the sample into focus with the highest magnification. Ensure that the specimen is centred over the stage opening and use the dioptric compensation to adjust the microscope to your eyes for optimal clarity.
What is the working distance for the microscope?
The normal working distance for the standard configuration is 80 mm for the LAB-10 model and 85 mm for the LAB-20 and LAB-30 models. This distance ensures proper operation and prevents damage to the optical components.
How do I clean the optical components?
If the optical parts need to be cleaned, first use compressed air to remove dust. If that is not sufficient, use a soft lint-free cloth with water and a mild detergent. As a final option, use a cloth moistened with a 3:7 mixture of ethanol and ether. Always ensure the area is well ventilated and avoid using these chemicals near heat sources or electrical equipment.
What should I do if the illumination is dark?
Check if the plug is connected to the illumination source. If the brightness is too low, adjust it to a proper setting. If the edge of the field of view is vignetted or the brightness is asymmetric, ensure the incident illuminator is correctly oriented.
How do I adjust the dioptric compensation?
Turn the zoom down to the lowest magnification and adjust the diopter compensation ring of the right eyepiece tube until the image is clear and sharp. Repeat the procedure for the left eyepiece. Check the focus across the entire zoom range to ensure it is parfocal.
What is the total magnification formula?
The total magnification used can be calculated by multiplying the eyepiece magnification, the zoom magnification, and the objective lens magnification. This formula helps determine the effective magnification when using different combinations of lenses and zoom settings.
How do I use the contrast disc?
Use the black/white contrast disc to enhance the contrast of the image when using incident illumination. Place the disc with the black side up if you are observing bright opaque objects to improve visibility and clarity.
What should I do if the image is not sharp?
Ensure the specimen is placed flat on the stage and check that the focus is adjusted properly. If the image is still not sharp, clean the lenses and check the alignment of the optical components. Adjust the focus system according to the manual for optimal results.
How do I maintain the microscope for long-term use?
Always keep the microscope vertically when moving it and avoid any mishandling. After use, turn off the light immediately, cover the microscope with the included dust cover, and store it in a dry, clean place. Regularly clean the optical components and follow the safety guidelines to ensure the longevity and performance of the microscope.
Related products from Optika
SFX-51
User manual 110 pages
B-190
User manual 44 pages
B-290
User manual 43 pages
B-290
User manual 144 pages
SZM-LED2
User manual 43 pages
SZM-LED1
User manual 43 pages
DM-5
User manual 48 pages
LAB
User manual 48 pages
SZM-4
User manual 48 pages
SZM-1
User manual 48 pages
B-150ALC
User manual 52 pages
B-150
User manual 52 pages
B-380 Series
User manual 64 pages
B-380 Series
User manual 80 pages
B-380 Series
User manual 222 pages
B-1000
User manual 62 pages
B-1000
User manual 80 pages
B-1000
User manual 100 pages
B-383LD2
User manual 64 pages
B-383LD2
User manual 222 pages