Product description:
Frequently Asked Questions
How do I activate the SMS function in the display?
To activate the SMS function in the display, go to the installation menu and select 'Advanced/Define System/GSM Information'. Choose 'Activate GSM - Yes'. Then, send the message 'aktiveranummer' to the SIM card number of your CTC SMS device. The system will respond with 'SMS-Control activated' once the mobile phone is registered.
What is the procedure to install CTC SMS?
To install CTC SMS, first attach the antenna to the side of the device. Insert the SIM card into the designated slot. Mount the CTC SMS unit securely. Remove the RJ45 connector from the display, connect the provided CAT5E-RJ45 cable, and link it to the CTC SMS unit. Ensure all cables are properly connected and secured during installation.
How do I change the room temperature for radiatorsystem 1?
To change the room temperature for radiatorsystem 1, send an SMS with the command 'rum1:XX', where XX is the desired temperature in degrees Celsius. For example, to set it to 22°C, send 'rum1:22'. The system will respond with a confirmation message indicating the temperature has been set.
How can I check the current operating status of CTC SMS?
To check the current operating status, use the command 'driftinfo'. CTC SMS will respond with an SMS containing temperature readings for outside, room 1, and room 2, along with any active alarms. This provides a comprehensive overview of the system's performance.
What should I do if there is a power outage?
In the event of a power outage, CTC SMS will send an SMS alarm indicating 'Strömavbrott' (Power Outage). Once power is restored, the system will send an SMS confirming 'Strömmen är tillbaka' (Power is Back). This ensures you are promptly notified of the power status.
How do I reset an alarm on the heat pump?
To reset an alarm on the heat pump, send the command 'larmreset' to the CTC SMS device. The system will respond with 'Larm återställt' if the reset was successful or 'Larmåterställning misslyckades' if it failed. This helps in managing and resolving alarms efficiently.
What are the requirements for the SIM card in CTC SMS?
The SIM card must be configured to operate without a PIN code. If the SIM card has a PIN code, it can be removed using a mobile phone or by your dealer. The SIM card should be inserted into the slot on the side of the GSM module. Ensure the SIM card is active and registered to receive and send SMS messages.
How do I deactivate a mobile phone number in CTC SMS?
To deactivate a mobile phone number, send the command 'stängnummer' from the registered mobile phone. CTC SMS will respond with an SMS confirming 'CTC SMS Styrning inaktiverad' (CTC SMS Control Deactivated). This removes the phone number from the active list.
What languages are supported for SMS commands?
The SMS function supports the languages available on the display. However, all commands must be sent in the language the display is set to. This ensures accurate interpretation and response from the system.
What should I do if I receive an 'No GSM signal' error?
If you receive an 'No GSM signal' error, check that the device has a clear connection to the GSM network. Ensure the SIM card is properly inserted and active. If the issue persists, verify the signal strength and consider relocating the device to an area with better coverage for optimal performance.