HACH LANGE SC200 (352 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the flow rate range of the ultrasonic flow sensor?
The ultrasonic flow sensor can measure flow rates from 0 to 999,999,999 with selectable flow rate and multiplier units, providing flexibility for various applications.
What is the accuracy of the ultrasonic flow sensor?
The sensor has an accuracy of 0.5% of the span, ensuring reliable and precise measurements under normal operating conditions.
What is the response time of the ultrasonic flow sensor?
The response time is less than 180 seconds to reach 90% of the value during a step change, allowing for quick adaptation to process variations.
What is the operating temperature range for the sensor?
The sensor can operate in temperatures ranging from -40 °C (-40 °F) to +90 °C (+194 °F), making it suitable for a wide range of environmental conditions.
What is the maximum depth for installation of the sensor?
The sensor can be installed in depths ranging from 0.25 m (10 in.) to 6 m (20 ft), with a tolerance of ±1 mm (0.039 in.), allowing for versatile deployment in different environments.
What is the power requirement for the sensor?
The sensor requires 12 VDC with a power dissipation of 0.5 W (0.042 A), ensuring efficient and safe operation without excessive energy consumption.
How should the sensor be mounted for installation?
The sensor must be mounted using the specified hardware, including socket screws, neoprene gaskets, and brackets, as detailed in the installation instructions to ensure proper alignment and stability.
What are the options for configuring the sensor's gauge parameters?
The sensor supports various gauge types, including V-notch weir, rectangular weir, rectangular flume, and others, allowing users to select the appropriate configuration based on their specific application and flow structure.
How do you set the measurement units for the sensor?
The measurement units can be set to millimeters (mm), meters (m), inches (in.), or feet (ft), and temperature units can be selected between Celsius (°C) and Fahrenheit (°F), providing flexibility for different user preferences.
What is the purpose of the filter setting in the sensor configuration?
The filter setting allows users to adjust the time constant for signal stability, with options ranging from 0 (no effect) to 60 seconds, helping to smooth out fluctuations in the measured data for more accurate readings.