Log in


or


google Continue with Google

Already have an account?

BEMKO SES15 (10 pages)

0 out of 5
0 review

Tags

Loading...

Languages available:

No exact matches found. Please change your query

PDF page 2
Loading...
Need help?

Need help?

Do you have a question about the product that is not answered in the manual?

  • Receive updates on solutions
  • Get answers to your question

Ask a question

Select image (Optional)

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Product description:

The BEMKO SES15 is a motion detector designed for security and lighting control applications. It employs passive infrared (PIR) technology to sense movement by detecting changes in infrared radiation within its coverage area. The device offers a detection range of up to 15 meters and a 180-degree angle, allowing for effective monitoring of medium-sized spaces. Key features include adjustable sensitivity settings for fine-tuning detection accuracy and a built-in timer for automated responses, such as activating lights or alarms. It supports wall or ceiling mounting for versatile installation and operates on low voltage, promoting energy efficiency. Compatible with various home automation systems, it enhances safety without unnecessary complexity.

Frequently Asked Questions

How does the BEMKO SES15 detect motion?

The BEMKO SES15 uses passive infrared (PIR) sensing to detect changes in infrared radiation caused by moving warm objects. This method is energy-efficient, reduces false positives from non-thermal movement, and reliably triggers lighting or alarms when motion is detected. For best performance, install it with a clear line of sight to the monitored area and avoid pointing it at heat sources.

What is the effective detection range and angle of the SES15?

The SES15 provides detection coverage up to approximately 15 meters with a horizontal angle of about 180 degrees. This makes it suitable for medium-sized rooms, corridors, and open areas. Positioning and mounting height influence effective range, so adjust placement to ensure the most critical zones fall within the sensor's field of view.

How should I mount the SES15 on a wall or ceiling for best results?

Mount the SES15 on a stable surface at the recommended height and orientation to maximize coverage, typically aiming slightly downward for walls and centered for ceilings. Avoid mounting near vents, radiators, or direct sunlight. Securely fasten the unit and keep its detection window free of obstructions for consistent operation.

Can I adjust the sensitivity and how should I set it?

Yes, the SES15 includes adjustable sensitivity settings to fine-tune detection accuracy. Start with a medium sensitivity and increase only if small movements are not detected, or decrease sensitivity if you experience false triggers from background motion or small pets. Fine-tuning during different times of day helps optimize performance.

What power supply does the SES15 require and is it energy-efficient?

The SES15 operates on low-voltage power, designed for energy-efficient performance in lighting and security applications. Low-voltage operation minimizes power consumption while maintaining reliable sensing. Ensure your power source meets voltage and current requirements of the sensor to guarantee stable operation and compatibility with connected equipment.

How does the built-in timer work and can I change the delay time?

The built-in timer allows the sensor to keep lights or alarms on for a set period after motion is detected. Delay times can be adjusted to suit occupancy patterns, from short intervals to longer hold times for sustained activity. Adjusting the timer reduces unnecessary energy use while ensuring user comfort and security.

Is the SES15 compatible with common home automation systems?

The SES15 is designed to integrate with many low-voltage lighting and home automation systems via standard control outputs. Compatibility depends on your system's input type and wiring, so match the sensor's electrical characteristics to your controller or relay to ensure seamless integration and reliable signaling.

How can I reduce false triggers from pets, curtains, or heating systems?

To reduce false triggers, lower the sensitivity, adjust the sensor angle, or change the mounting location to avoid direct detection of small pets, moving curtains, or HVAC airflow. Use zoning to focus detection on human-sized movement and consider mounting at a height that minimizes detection of low-level motion.

What routine maintenance does the SES15 require to remain reliable?

Routine maintenance is minimal: regularly clean the sensor lens with a soft, dry cloth to remove dust, check that the housing remains sealed against moisture, and verify mounting stability. Periodic functional tests ensure the sensor continues to detect motion correctly and that electrical connections remain secure and corrosion-free.

What troubleshooting steps help if the SES15 does not detect motion?

If the SES15 fails to detect motion, first verify correct power supply and secure wiring connections. Clean the sensor window, check mounting orientation and height, and test with higher sensitivity settings. If issues persist, replace faulty wiring or consult a qualified technician to inspect the unit and system integration.

Send answer

Your opinion matters to us

Do you think we can improve or add something? Are there features missing or do you have suggestions for improvement? We would love to hear from you.

Give a rating

5 out of 5