Product description:

The ESYLUX PD-C360i/12 mini KNX is a compact ceiling-mounted motion detector for indoor use, offering a 360-degree detection angle to cover an entire room. It features a detection range of up to 12 meters, enabling precise sensing of movement through passive infrared technology. This device is fully compatible with the KNX building automation standard, allowing integration with other KNX systems for functions such as automated lighting control, energy management, and occupancy-based operations. Its miniature design ensures discreet installation, making it suitable for various residential and commercial environments. The detector operates reliably in different lighting conditions, contributing to efficient space utilization and reduced energy consumption.

Frequently Asked Questions

What detection area does the PD-C360i/12 mini KNX cover?

The PD-C360i/12 mini KNX provides 360-degree coverage and a detection range of up to 12 metres. Actual coverage depends on mounting height and room geometry, so positioning the sensor centrally and at recommended ceiling heights maximises reliable motion sensing for complete-room control.

How does the passive infrared sensor detect movement?

The detector uses passive infrared technology to sense changes in heat distribution caused by moving people. It detects motion when a warm body crosses sensor zones, so it recognises movement rather than static presence and is resistant to false triggers from stationary objects.

How do I integrate this detector into a KNX building automation system?

Integration is done via the KNX bus: the detector communicates using KNX group addresses and parameters. During commissioning you assign group addresses and configure functions like lighting control and occupancy logic using the KNX commissioning tools commonly used for system setup.

What installation height is recommended for reliable detection?

For optimal performance install the detector at typical ceiling heights of around 2.5 to 3.5 metres. Higher ceilings may reduce sensitivity and alter the detection pattern, so adjust sensitivity parameters after installation to maintain consistent coverage.

Can the PD-C360i/12 mini KNX distinguish between people and pets?

The PIR sensor primarily detects motion and thermal changes, so it cannot reliably identify people versus pets. You can reduce pet-related false triggers by adjusting sensitivity, choosing appropriate mounting height, and configuring time delays within the KNX settings.

How does ambient light influence the detector's operation?

The motion detection itself is based on infrared and works independently of ambient light. The detector can provide brightness information to KNX so lighting activation can be suppressed when sufficient daylight is present, reducing unnecessary switching and saving energy.

What wiring and power requirements are needed for the KNX detector?

The detector must be connected to the KNX bus using standard KNX wiring practices and meet applicable electrical safety regulations. A qualified electrician should perform the installation, ensure correct bus topology, and supply power according to KNX system requirements.

How can I adjust sensitivity, timeout and other operating parameters?

Operating parameters such as sensitivity, hold time, retriggering and daylight thresholds are configured through the KNX commissioning interface. Adjust these settings during commissioning and test in real conditions to optimise detection behaviour and avoid unwanted switching.

Is this detector suitable for recessed or surface ceiling mounting?

The PD-C360i/12 mini KNX is designed for discreet ceiling mounting and can be installed in typical suspended or solid ceilings. Mounting options depend on available accessories and ceiling construction, so choose the appropriate mounting method for a secure, flush finish.

What maintenance is required to ensure long-term reliable operation?

Maintenance is minimal: keep the sensor lens free of dust and contamination using a soft, dry cloth, periodically inspect connections for corrosion or loosening, and verify KNX parameter settings after major changes to the room layout to ensure continued reliable detection.