Product description:
Frequently Asked Questions
What is the function of the MB LAN 2 module?
The MB LAN 2 module serves as an interface between the heating system and the network (LAN) and allows system control via smartphone. It cannot be combined with the FR 50 regulator, which operates on room temperature.
What components are included in the delivery package?
The delivery package includes the module, a power supply unit with connecting cable, a CAT 5 LAN cable, a mounting kit, and the installation manual.
What are the technical specifications of the MB LAN 2 module?
The MB LAN 2 module has dimensions of 151 × 184 × 61 mm. It supports BUS systems like EMS 2, HT, and CAN, and has a power supply of 230V AC/7.5 V DC, 700 mA. The interface includes LAN at 10/100 MBit/s (RJ45). It consumes 1.5 VA and operates within a temperature range of 0 to 50 °C with IP20 protection.
How should the CAN bus be connected to the module?
To connect the CAN bus to the module, set both switches on the CAN connection to the correct position for proper system connection. If the module is an end point, set both switches to ON; if it is connected to a junction, set them to OFF.
What is the maximum length of the BUS connection?
The maximum total length of the BUS connection between all participants in the BUS system varies depending on the type of BUS: for a two-wire BUS/EMS 2, it can be up to 300 meters with a conductor cross-section of 1.50 mm². For CAN, the maximum length is 30 meters with shielded, twisted pair cables.
How do you connect the module to the EMS2/two-wire BUS system?
Connect the participants in the bus sequentially with two contacts. Participants in the bus [B] connected through a distribution box [A] should be connected in a star configuration. Shield the cable if there are external inductive influences to protect against interference from high-voltage cables, contact lines, traffic lights, radios, and other sources.
What should be done if the module's LED is red during startup?
If the LED on the module is red during startup, it indicates that no BUS or LAN connection has been established. Ensure that the connections are properly made and check the setup steps outlined in the manual.
What is the purpose of the TSW switch on the module?
The TSW switch on the module is used for connecting to the CAN bus. It should be set appropriately based on whether the module is an end point or connected to a junction.
What types of cables are suitable for the BUS system?
Suitable cables for the BUS system include LiYCY 2 x 0.75 (TP) for the two-wire BUS/EMS 2 and 2 × 2 × 0.3 mm² shielded, twisted pair cables for CAN. These cables ensure reliable communication and reduce interference.
How should the CAN bus be connected to the heat pump?