RIB L1-CRX (68 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the maximum speed of the K800 FCM FAST operator?
The K800 FCM FAST operator has a maximum speed of 21 meters per minute.
What is the maximum gate weight supported by the K800 FCM FAST?
The K800 FCM FAST supports a maximum gate weight of 800 kilograms or 1760 pounds.
What type of rack should be used with the K800 FCM FAST?
Only a metal rib rack should be used with the K800 FCM FAST. It is recommended to use the ACS9050 module 4 with cataphoresis treatment.
Where should the K800 FCM FAST be installed?
The K800 FCM FAST should be installed on movable parts that slide alongside the closing column. It should not be applied to movable parts that close near the column.
What is the maximum thrust of the K800 FCM FAST?
The K800 FCM FAST has a maximum thrust of 700 Newtons.
What is the maximum torque of the K800 FCM FAST?
The K800 FCM FAST has a maximum torque of 24 Newton-meters.
What safety precautions are required during installation?
During installation, it is important to install a magnetic-thermal circuit breaker with a minimum contact opening of 3 mm, ensure proper cable wiring according to IEC 364, and position photocells correctly at a height not exceeding 70 cm and a distance not exceeding 20 cm from the gate movement plane. All safety devices must comply with EN 12453 standards.
What is the power supply requirement for the K800 FCM FAST?
The K800 FCM FAST requires a power supply of 230 volts at 50/60 Hz.
What is the recommended cable type for installation?
The recommended cable type for installation is H05RN-F with a minimum cross-sectional area of 1.5 mm², following IEC 364 and local installation regulations.
What is the safety height for the manual release mechanism?
The manual release mechanism should be installed at a height lower than 1.8 meters to ensure safe access and operation.