Product description:
Frequently Asked Questions
How should I install the VULCAN heater?
The heater must be installed horizontally or vertically, allowing enough space for pipe connections and wiring. It should be securely fixed to a firm base or wall. Ensure it is positioned downstream of the filter and upstream of any water treatment plant.
What is the minimum pipe size required?
The pipe work connecting to and from the heater must have a minimum bore (internal diameter) of 1¼” (32mm). The return pipe should include a safety loop or 'kick-up' near the heater to ensure it remains full of water during operation.
How do I reverse the water flow direction?
To reverse the flow, rotate the flow switch 180 degrees. Ensure the arrow on the flow switch body aligns with the water flow direction. Always lock it in the correct orientation perpendicular to the flow.
What are the minimum flow rates for the heater?
The heater requires a minimum flow rate of 1,000 litres/hour (220 UK gallons/hour) for 3–6 kW models and 4,000 litres/hour (880 UK gallons/hour) for 9–15 kW models. Exceeding these may require a bypass to prevent damage.
What water quality parameters are required?
The water must have a pH of 6.8–8.0, total alkalinity of 80–140 ppm, chloride content under 150 mg/litre, free chlorine under 2.0 mg/litre, total bromine under 4.5 mg/litre, and TDS/Calcium hardness between 200–1,000 ppm.
How do I set the desired water temperature?
For analogue models, rotate the temperature dial to the desired setting. For digital models, press the 'P' button to display or modify the temperature, then use the 'Up' or 'Down' buttons to adjust it to your required set point.
What is the time delay function for the digital thermostat?
The digital thermostat includes a time delay to prevent rapid switching of the heater, which can cause overheating. It limits the heater from cycling more than once every two minutes, indicated by the flashing red indicator.
What is the differential setting on the heater?
The differential is the temperature difference that must occur before the heater switches back 'On'. It is set to 0.6º C to prevent overheating of internal components due to frequent cycling.
How does the high temperature alarm work?
The heater has a high temperature alarm that activates if the water temperature is 2º C or more above the set point. The alarm flashes 'HI' in the display. Once the temperature returns to the set point, the alarm stops, and the heater resumes normal operation.
How long will it take to heat my pool?
Assuming no heat losses and a heater sized at 1.5 kW per 1,000 UK gallons of water, it will take approximately 2 days of continuous operation to raise the pool temperature from tap to swimming temperature. Cold weather and higher ambient temperatures will slow the heating process.