Product description:

The PL330TP is a precision power supply from Thurlby Thandar Instruments. It provides stable and accurate voltage and current outputs, making it suitable for a wide range of laboratory and industrial applications. The device features a digital display for easy monitoring of output parameters and includes multiple protection functions to ensure safe operation. Its compact design allows for easy integration into test setups and measurement systems.

Frequently Asked Questions

What is the output voltage range for local operation?

The main output voltage range for local operation is 0-32V nominal, with a current range of 0-3.1A nominal. The output voltage can be set using coarse and fine controls with a resolution of less than 5mV across the range.

How does the output mode work?

The power supply operates in constant voltage or constant current modes with an automatic cross-over. When in constant current mode, the decimal points flash to indicate this mode.

What is the output impedance for constant voltage and current?

The output impedance for constant voltage is less than 5 mΩ at 1kHz, while for constant current it is typically 50 kΩ with a voltage limit at maximum.

What are the output protection features?

The power supply provides up to a maximum output voltage plus 20 volts forward, with a diode clamp for reverse voltages and up to 3A reverse current. This ensures protection against overvoltage and reverse polarity.

What is the load and line regulation performance?

The load and line regulation is less than 0.01% of the maximum output for a 90% load change or a 10% line change, ensuring stable output under varying conditions.

What is the ripple and noise level?

The ripple and noise level is typically less than 1 mV RMS, ensuring a clean and stable output signal.

What is the transient response time?

The transient response time is less than 20 µs to within 50 mV of the setting for a 90% load change, allowing for quick stabilization after load changes.

What is the temperature coefficient?

The temperature coefficient is typically less than 100 ppm/°C, ensuring minimal variation in output with temperature changes.

What is the meter resolution and accuracy?

The meter has a resolution of 10 mV and 1 mA over the entire range. The voltage accuracy is 0.1% of the reading plus 1 digit, while the current accuracy is 0.3% of the reading plus 1 digit.

What are the remote operation specifications?

Remote operation specifications include a 12-bit resolution for both voltage and current settings, with a voltage setting accuracy of 0.1% ± 10mV and a current setting accuracy of 0.2% ± 2mA. The readback resolution is 10mV and 1mA, and the readback accuracy is 0.1% of the reading plus 1 digit for voltage and 0.3% of the reading plus 1 digit for current.