Log in


or


google Continue with Google

Already have an account?

Bahco TAS14 (612 pages)

0 out of 5
0 review

Tags

Loading...

Languages available:

No exact matches found. Please change your query

PDF page 1
Loading...
Need help?

Need help?

Do you have a question about the product that is not answered in the manual?

  • Receive updates on solutions
  • Get answers to your question

Ask a question

Select image (Optional)

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Product description:

The Bahco TAS14 is a high-quality power tool designed for professional use. It features a robust construction and advanced engineering to ensure durability and long-lasting performance. The tool is equipped with a powerful motor that delivers high torque, making it suitable for demanding tasks. Its ergonomic design enhances user comfort during extended use. The TAS14 is ideal for applications in construction, woodworking, and metalworking. It includes various safety mechanisms to protect the user and ensure reliable operation under different working conditions.

Frequently Asked Questions

What are the safety precautions when using the electronic torque-angle wrench?

Always wear safety goggles for both user and bystanders. Ensure all components, including adaptors and sockets, are rated to match or exceed the torque being applied. Avoid over-torquing to prevent breakage or injury. Never use the tool to break fasteners loose. Store the tool in a dry place and remove batteries if not used for more than 3 months.

How do I ensure accurate measurements with the tool?

Work must not move in angle mode to ensure accuracy. Periodic recalibration is necessary to maintain accuracy. Always turn on the tool before applying torque to ensure the torque is being measured. Verify calibration if the tool has been dropped or if you suspect its capacity has been exceeded.

What are the torque and angle accuracy specifications?

Torque accuracy is ±2% ±3% of reading for 20% to 100% of full scale, ±4% ±6% for 10% to 19%, and ±8% ±10% for 5% to 9%. Angle accuracy is ±1% of reading plus ±1° angular velocity for speeds between 10°/sec and 180°/sec. Temperature drift is -0.12° per °C for angle and +0.01% of reading per °C for torque.

How do I select units of measurement for torque and angle?

Press the UNITS button on the target torque screen to cycle through available units: ft-lbs, in-lbs, in-oz, kgm, kg-cm, dNm, and cNm. The units will change based on the torque range selected. This allows for flexibility in measurement depending on the application.

How do the progress lights indicate torque or angle progress?

The progress lights indicate the percentage of the target torque or angle reached. Yellow lights indicate 40%, 60%, and 80% of the target. Green indicates the target has been reached. Red indicates the target has been exceeded by 4% or more, or the maximum preset target has been reached.

What should I do if the tool exceeds the torque or angle target?

If the tool exceeds the torque or angle target, the red progress light will indicate this. The tool will also emit an audible alert and vibrate. If this occurs, stop applying torque immediately. The peak torque or angle reading will flash on the display for 5 seconds, and you can recall it by pressing the backlight button.

How do I recalibrate the tool if needed?

To recalibrate the tool, ensure it is on a stable surface with no torque applied. If the tool has been dropped or you suspect its capacity has been exceeded, verify calibration. For angle mode, the tool will automatically begin the zeroing process after 2 seconds if it is the first time angle mode is selected following a power on.

How do I set the target torque or angle?

To set the target torque or angle, use the UP and DOWN buttons to adjust the value on the target screen. Once the desired value is set, press the ENTER button to confirm. The tool will then display the target value and wait for you to apply the torque or rotate the tool to reach the target.

How do I recall the last peak torque or angle reading?

To recall the last peak torque or angle reading, press and hold the backlight button for approximately 3 seconds. The peak torque or angle will flash for 5 seconds on the display. This allows you to review the maximum value recorded during the last measurement cycle.

How do I set the head length for the tool?

To set the head length, from the target torque or angle screen, press and hold the ENTER button for 3 seconds. Select 'SET HEAD LENGTH' and enter the length of the head, adapter, or extension being used. The default unit is inches, but you can switch to millimeters using the UNITS button. The head length will be used to adjust the offset for accurate measurements without requiring recalibration.

Send answer

Your opinion matters to us

Do you think we can improve or add something? Are there features missing or do you have suggestions for improvement? We would love to hear from you.

Give a rating

5 out of 5
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.