Product description:
Frequently Asked Questions
What is the maximum power output of the generator?
The maximum power output of the generator is 44 kW, which corresponds to 38,000 kcal/h and 150,000 Btu/h.
What types of fuel can be used with the generator?
The generator can only be operated with diesel or kerosene. Using gasoline, naptha, paint thinner, alcohol, or other highly flammable fuels is prohibited.
How often should the fuel filter be cleaned or replaced?
The fuel filter should be cleaned or replaced every 1000 hours of operation or as needed, depending on usage conditions.
What is the recommended distance from flammable materials to the generator?
The generator should be kept at a minimum safe distance from flammable materials. The front outlet should be at least 2.5 meters away, while the sides, top, and back should be at least 1.5 meters away.
How do you reset the generator if it shuts off due to fuel exhaustion?
If the generator shuts off due to fuel exhaustion, refill the fuel tank and reset the generator by following the reset procedure outlined in section 6.2.
What is the correct procedure for starting the generator?
To start the generator, follow all safety instructions, check for fuel in the tank, close the tank cap, connect the power plug to the electrical supply, set the ON/OFF switch to ON, and ensure the generator starts within a few seconds. If it does not start, refer to section 11 for troubleshooting.
How do you adjust the compressor pressure?
To adjust the compressor pressure, identify the correct pressure from the technical data table, remove the metering attachment screw, install a manometer, turn the adjustment screw clockwise to increase pressure or counterclockwise to decrease it, then reinstall the metering attachment.
What should be done if the generator fails to start?
If the generator fails to start, possible causes include lack of fuel, incorrect fuel type, faulty ignition system, or issues with the air filter. Check these components and follow the troubleshooting steps in section 11.
How should the generator be stored when not in use?
When storing the generator, empty the fuel tank, clean it with clean fuel, close the tank cap and any drain valve, and dispose of the fuel properly. Store the generator in a dry, secure location and keep it level to prevent fuel leakage.
What is the recommended voltage and frequency for the generator?
The generator should be connected to an electrical supply with a voltage and frequency specified on the identification plate, typically 220-240 V / 50 Hz or 110-120 V / 50 Hz, depending on the model.
Related products from Master
B100CED
User manual 118 pages
B100CED
User manual 135 pages
B100CED
User manual 21 pages
B35CED
User manual 21 pages
B35CED
User manual 118 pages
B35CED
User manual 129 pages
B35CED
User manual 135 pages
B70CED
User manual 135 pages
B70CED
User manual 129 pages
B70CED
User manual 118 pages
B70CED
User manual 21 pages
BLP 17M DC
User manual 25 pages
BLP 17M DC
User manual 197 pages
BLP 53 kW
User manual 36 pages
BLP 53 kW
User manual 188 pages
BLP 11
User manual 41 pages
BLP 11
User manual 209 pages
BLP 27
User manual 41 pages
BLP 27
User manual 209 pages
BLP 73E
User manual 41 pages