Dräger X-act 5000 Basic (108 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the purpose of the Dräger X-act 5000 Basic?
The Dräger X-act 5000 Basic is an automatic pump used with tubes or sampling systems to measure gases, vapors, and aerosols in air or technical gases. It is designed for spot check measurements and sampling in hazardous areas.
How do I start a measurement with the Dräger X-act 5000 Basic?
To start a measurement, select the appropriate operating mode from the password-protected menu. For tube measurements, choose 'Measurements using tubes', and for sampling, select 'Sample taking'. Ensure the device is properly charged and the tubes are correctly connected.
What are the safety precautions for using the Dräger X-act 5000 Basic?
Only trained and competent users should operate the device. Follow all local regulations, use genuine Dräger parts, and avoid modifying the device. Ensure the device is not used if faulty or incomplete, and report any component faults to Dräger.
How do I interpret the LED indicators on the device?
Green flashing LEDs indicate the measurement is complete, while red flashing LEDs signal an error, such as a failed leak test. These indicators will continue to flash until the 'OK' key is pressed to acknowledge the status.
What is the battery capacity indicator on the device?
The display shows battery capacity with different icons. A full battery is indicated by a solid icon, while a flashing icon signals low battery. When the battery is below 16%, the icon begins to flash, and the device will not operate until it is recharged.
How do I change the SO3 filter?
To change the SO3 filter, access the password-protected menu and select 'Change SO3 Filter'. Enter the date of the filter change for record-keeping. Ensure the filter is replaced according to the maintenance schedule to maintain accurate measurements.
What are the operating modes available for the device?
The device offers several operating modes, including 'Measurements using tubes' for air or technical gas analysis and 'Sample taking' for active sampling of volatile substances. The user can select the mode at the start of a measurement.
How do I perform a leak test?
A leak test can be performed through the password-protected menu. The test is mandatory after a set number of strokes, typically 1000 strokes (100 L). If the test fails, an error message will appear, and the measurement will not proceed until the issue is resolved.
What is the significance of the year of manufacture on the device?
The year of manufacture is indicated by the third letter in the serial number. For example, 'K' corresponds to 2017. This information helps in determining the device's age and ensures proper maintenance and replacement schedules.
What approvals does the Dräger X-act 5000 Basic have?
The device is approved for use in hazardous areas and carries certifications such as CE, IECEx, and UL/cUL. It is intrinsically safe when used with approved power supplies and is designed to meet international safety and performance standards.