Product description:
Frequently Asked Questions
What is the minimum water pressure required for the system to operate?
The system requires a minimum water pressure of 1.4 bar (20 PSI) to function effectively. Ensure the pressure does not exceed 8.5 bar, and install a pressure regulator if necessary.
How should the brine tank be filled during installation?
Fill the brine tank with approximately 25mm of water above the grid plate (if used), or to the top of the air check. Do not add salt at this stage.
What should be done if the unit is not equipped with a bypass valve?
Always provide a bypass valve during installation. Turn on the main water supply, open a cold soft water tap, and let it run until the system is free from foreign material.
How do you initiate a manual regeneration cycle?
Press and hold the Extra Cycle button for five seconds to start a manual regeneration. Position the valve to 'brine draw and slow rinse' to draw water from the brine tank until the air-check valve is blocked.
What is the purpose of the power backup feature in the Storm timer?
The power backup feature keeps track of time and the passage of days for at least 12 hours during a power failure. It stores the remaining volume of water at the time of the failure and resumes operation once power is restored.
How does the meter delayed control function?
The meter delayed control measures water usage and initiates regeneration after the calculated system capacity is depleted. It uses the feedwater hardness and reserve settings to determine when regeneration is needed.
What should be done if a power failure occurs during regeneration?
The control will save the current valve position before shutting down. When power is restored, it resumes the regeneration cycle from the point of failure. The valve will remain in its current position until power is restored.
How do you set the time of day on the timer?
Press and hold the Up or Down arrow buttons until the programming icon replaces the service icon. Adjust the time using the Up or Down arrows, then press the Extra Cycle button to save the setting.
What is the range for salt dosage settings on the timer?
The salt dosage range is 3-18 lbs (English) or 50-290 grams per liter (Metric). Adjust the setting using the Up or Down arrow buttons.
How do you adjust the regeneration time on the timer?
Press the Mode button to cycle through programming options. Use the Up or Down arrow buttons to adjust the regeneration time, ensuring it aligns with your system's requirements.
Related products from Pentair
JUNG PUMPEN
User manual 80 pages
Ultra-Flow
User manual 72 pages
Fleck 2850 NXT2
User manual 36 pages
FLECK 9100 SXT
User manual 36 pages
FREEFLO
User manual 40 pages
FREEFLO FFL-071
User manual 40 pages
IntelliFlo UltraFlow VSD
User manual 242 pages
IntelliFlo WhisperFlo VSD
User manual 242 pages
JUNG PUMPEN WCFIX PLUS
User manual 48 pages
SIMER 5
User manual 48 pages
JUNG WCFIX PLUS
User manual 48 pages
US 102
User manual 56 pages
US 102
User manual 50 pages
US 73 H
User manual 50 pages
US 73 H
User manual 56 pages
US 75
User manual 56 pages
US 75
User manual 50 pages
US 153
User manual 50 pages
US 153
User manual 56 pages
US 105
User manual 50 pages