Product description:
Frequently Asked Questions
How to install the FWS-2-60 freshwater station?
Installation of the FWS-2-60 freshwater station must be carried out by a certified professional. Ensure the installation location is frost-free. Use the provided mounting materials, including two M10x100 bolts, six M10 nuts, and four M10 washers. Secure the unit properly and follow the hydraulic and electrical connection instructions as outlined in the manual.
What are the electrical connection requirements?
The electrical wiring of the FWS-2-60 is pre-installed. Connect the unit to the power supply (230 V/AC, 50-60 Hz) using the provided cable. Ensure all electrical work is performed in accordance with local regulations and safety standards. Proper grounding is required at the mounting bracket of the FWS-2-60.
How to connect the hydraulic system?
The freshwater station's potable water side must be protected against overpressure using a safety valve with a maximum pressure of 10 bar. Optional, a potable water expansion tank can be installed. Connect the piping according to the provided diagram. For galvanized pipes and fittings, follow the installation sequence to prevent electrochemical corrosion. Ensure all connections are made after the piping is properly sealed.
What is the recommended temperature setting for the system?
The thermal setpoint regulator is pre-set to 50°C. The adjustment range is limited to 3.25°C by default. Use the red and blue temperature limit pins (Memory-Clips) to set or fix the temperature range. Turning the regulator clockwise lowers the temperature. It is recommended to maintain a temperature difference of at least 12 K between the storage tank and the desired hot water temperature.
How to install the ZP-3 circulation pump set?
The ZP-3 circulation pump set can be installed as an optional add-on. Remove the blind cap splint from the FWS-2-60 and take off the blind cap. Insert the ZP-3 unit until it clicks into place and secure it with the splint. The pump set includes a pump with push-in connection, a ball valve, and an eccentric. Ensure no force is applied to pre-mounted components during installation.
What are the safety precautions during installation?
Always follow local safety regulations and technical standards such as DIN 1988, DIN 4708, and VDE 0100. Ensure the unit is installed in a frost-free area. Avoid overpressure in the system to prevent leaks or damage to the storage tank. Use proper grounding and follow all electrical safety procedures.
How to perform the initial commissioning?
Commissioning of the system must be carried out by a certified professional. Check the functionality and tightness of the entire system, including components pre-installed by the manufacturer. Open the ball valves slowly to prevent pressure surges during filling. Continue filling and flushing until the system is completely deaerated. Any audible flow noise indicates trapped air, which should be removed using the pump.
What are the technical specifications of the FWS-2-60?
The FWS-2-60 is a freshwater module designed for hot water circulation. It includes a plate heat exchanger, a flow switch, a thermostat head, and a heating pump. The system is compatible with various installation configurations, including wall mounting and integration with a buffer tank. Technical details such as dimensions, flow rates, and pressure ratings are provided in the manual.
How to maintain the system?
Annual maintenance by a qualified technician is recommended. Check for leaks, ensure proper insulation, and verify the functionality of all components. Monitor the temperature settings and adjust as needed. Regularly inspect the pump set and hydraulic connections for signs of wear or damage. Keep the system clean and free from debris to ensure optimal performance.
What are the disposal and recycling instructions?
Old equipment must be disposed of by qualified professionals, separating electrical, gas, and refrigerant components. Do not dispose of the unit in household waste. Recycle packaging materials, recyclable plastics, and fillers through appropriate recycling systems or recycling centers. Follow local environmental regulations and ensure proper disposal of hazardous materials.