Frequently Asked Questions
What are the model numbers for the cooker hood?
The model numbers for the cooker hood are F60.2, F90.2, BT16.3, BT19.3, BT6.3, and BT9.3.
Where can I find the model number and serial number?
The model number and serial number can be found on the Rating Plate and your sales invoice. Please record this information for future reference.
What is the minimum distance between the cooker top and the bottom of the cooker hood?
The minimum distance between the cooker top and the bottom of the cooker hood should be 700 mm for electric and gas cookers, and 800 mm for coal or oil cookers.
What safety precautions should I take when installing the cooker hood?
Ensure the hood is installed according to the instructions, avoid overhanging cabinets, keep children away, and never tamper with the unit. Always disconnect the power before performing any maintenance.
What type of flue is required if the hood is installed above a gas appliance?
If the hood is installed above a gas appliance, the flue must be sealed or balanced to ensure proper ventilation and safety. Check the Gas Safety Codes of Practice for specific requirements.
What are the requirements for the ducting system when using the extractor function?
The ducting must be fire retardant, have no bends sharper than 90 degrees, and maintain the same diameter as the outlet hole throughout the system to ensure efficiency.
How should I install the cooker hood on the wall?
Install the hood on the wall at least 700 mm above the cooking surface. Mark and drill holes for the mounting bolts, and secure the unit properly using the provided hardware.
What should I do if I want to use the hood as a suction ventilator?
Before installation, decide whether you want to use the hood as a suction ventilator. Follow the installation instructions carefully and ensure the ducting system meets the specifications for the suction mode.
How do I install the grease filters?
Remove the metal grease filters before installation. Ensure they are properly secured and cleaned regularly. Do not clean behind the filters as this can be dangerous.
What are the requirements for using the air cleaner (recirculation) function?
If using the air cleaner function, ensure the hood is connected to an internal ducting system. Install two active carbon filters to absorb kitchen vapours and ensure proper ventilation.