Product description:

The Bosch DWT126851 is a range hood designed for efficient extraction of cooking vapors and odors. It features a powerful motor and multiple fan speeds to ensure optimal performance in the kitchen. The unit includes a grease filter and a washable aluminum filter for easy maintenance. Its modern design integrates seamlessly into the kitchen environment. The range hood is suitable for use above cooktops and offers a combination of suction power and quiet operation.

Frequently Asked Questions

How does the range hood remove kitchen steam?

The range hood's fan draws kitchen steam into the unit and directs it through the grease filter into the open air. The grease filter captures fatty particles from the steam, keeping the kitchen largely free of grease and odor.

What happens if the range hood is used in exhaust mode with a chimney-dependent burner?

When using the range hood in exhaust mode alongside chimney-dependent burners (such as gas, oil, or coal heating appliances, water heaters, etc.), ensure sufficient fresh air supply is available for combustion. A safe operation is possible if the negative pressure in the combustion chamber does not exceed 4 Pa (0.04 mbar). This can be achieved through non-sealable openings, such as doors, windows, or with air intake/exhaust wall boxes, or other technical measures like interlocking mechanisms.

Can the range hood operate in recirculation mode with an activated carbon filter?

Yes, the range hood can operate in recirculation mode with an activated carbon filter without restrictions. The activated carbon filter binds odor-causing substances, while the grease filter captures fatty particles. Ensure the activated carbon filter is installed as described in the filter and maintenance section.

What should I do if the range hood is not working properly?

If the range hood is not working properly, first check the filter and maintenance section. If the display shows a # or C, refer to the filter and maintenance section. If the hood is not operable, unplug it or turn off the circuit breaker for about a minute, then restart it. For further issues, contact the service department.

How often should the grease filter be cleaned?

In normal operation (1 to 2 hours daily), the metal grease filters should be cleaned once a month. Cleaning can be done in the dishwasher, where slight discoloration may occur. Ensure the filter is loosely placed and not compressed. Avoid cleaning heavily saturated filters with dishes.

What should I do if the activated carbon filter is saturated?

When the activated carbon filter is saturated, the display shows a C and a signal tone is emitted. The signal is turned off when the fan is switched off. Replace the activated carbon filter as soon as possible to prevent odor-causing substances from being released.

How do I clean the range hood?

Clean the range hood by unplugging it or turning off the circuit breaker. Do not use abrasive sponges or sand, soda, acid, or chloride-containing cleaning agents. Use hot dish soap or mild window cleaner instead. Wipe away dried dirt with a damp cloth, and avoid scraping it off. Clean accessible housing parts of accumulated grease to prevent fire hazards.

What should I do if the range hood is emitting a strange smell?

A strange smell may indicate a saturated activated carbon filter or a clogged grease filter. Check the filter and maintenance section for instructions on replacing or cleaning the filters. Ensure the filters are properly installed and functioning.

How do I replace the halogen lamps?

To replace the halogen lamps, first turn off the range hood and unplug it or turn off the circuit breaker. Remove the lamp ring using a screwdriver, replace the halogen bulb (standard 12V, max 20W, G4 socket), and reassemble the lamp ring. Ensure the new bulb is properly seated and the power is restored.

What should I do if the range hood is not responding to controls?

If the range hood is not responding to controls, unplug it or turn off the circuit breaker for about a minute, then restart it. If the issue persists, check the filter and maintenance section or contact the service department. Ensure the filters are clean and the power supply is stable.