Product description:

The FALMEC plane wall range hood is designed for installation directly into the wall surface, offering a sleek and integrated appearance. It features efficient grease and smoke extraction, ensuring optimal air quality in the kitchen. The unit is equipped with powerful motors and multiple speed settings for flexible performance. It includes a durable filter system that is easy to clean and maintain. The design allows for seamless integration into modern kitchen environments, providing both functionality and aesthetic appeal.

Frequently Asked Questions

What is the minimum distance between the cooker and the hood?

The minimum distance between the cooker and the lowest part of the hood is indicated in Fig. A on page 4. Generally, this distance must be at least 65 cm (25.6") when the hood is placed on gas cookers.

What are the safety instructions for installation?

Installation operations must be carried out by skilled and qualified installers in accordance with the instructions in this booklet and in compliance with the regulations in force. Before installation, check the integrity and function of each part. Do not proceed with installation if anomalies are noted. Always use personal protective equipment and adopt prudent and proper conduct.

What are the electrical safety requirements?

The electrical system to which the hood is to be connected must be according to standard and compulsorily supplied with an earthed connection in compliance with safety regulations in the country of use. It must also comply with European standards regarding radio antistatic properties. Before installation, check that the electrical mains power supply corresponds with what is reported on the identification plate located inside the hood.

What are the warnings for using the hood?

Do not use the hood if the power supply cable or other components are damaged. Disconnect the hood from the electrical power supply and contact the Dealer or an authorised Servicing Department for repairs. Do not modify the electrical, mechanical and functional structure of the equipment. Do not use the hood outdoors and do not expose it to atmospheric agents (rain, wind, etc.).

What are the cleaning and maintenance warnings?

Before cleaning or carrying out maintenance operations, disconnect the equipment by removing the plug or switching of the main switch. Do not use the hood with wet hands or bare feet. Always check that all electrical parts (lights, extractor fan) are off when the equipment is not used. The maximum overall weight of any objects placed or hung on the hood must not exceed 1.5 Kg.

What are the fumes discharge requirements?

Do not connect the equipment to discharge pipes of fumes produced from combustion (for example boilers, fireplaces, etc.). Before installing the hood, ensure that all standards in force regarding discharge of air out of the room have been complied with. The fumes outlet pipe must have a diameter not less than that of the hood fitting, a slight slope downwards in the horizontal sections, and the minimum required number of bends.

How should the hood be assembled?

Place the support bar (S) on the installation wall at a height (H) from the cooker indicated in the figure (Fig. 1). Use a spirit level to check the horizontal alignment and draw 2 marks at each end of the support bar, this is where the holes will be drilled (Fig. 2 - 3). Drill the holes, insert 2 expansion plugs (ø 8mm) and fasten the bar with the relative screws (V1) (Fig. 4).

What are the operating instructions for the hood?

Switch on the hood at least one minute before starting to cook: this enhances the airflow to convey fumes and vapours towards the suction surface. After cooking, leave the hood operating until complete extraction of all vapours and odours. If required, by means of the Timer function, it is possible to set hood auto switch-off after 15 minutes of operation.

How should the filters be washed or replaced?

The hood is assembled with two different types of filters: metal ones (washable) and active carbon ones (non-washable). The former must be cleaned every 30 hours of use (for versions with electronic push button control panel, the fixed red light indicates that they need to be washed), the latter are to be replaced every 3-4 months, depending on the use of the hood.

How to use the electronic push button control panel?

Pressing the key with the motor active at any speed activates the Timer function: this function determines the auto switch-off of the hood after 15 minutes of operation. Activation of the function is signalled by a RED flashing light. With the Timer function active, the hood can still be switched off by the user at any time by pressing the key: the function will be automatically disabled and the RED light will turn off.