WIKA A2G-100 (84 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the model number of the PID controller?
The PID controller is model A2G-100, designed for controlling air flows or differential pressures in ventilation and air-conditioning applications.
What are the key features of the A2G-100 PID controller?
The A2G-100 PID controller provides 0 ... 10 V or 4 ... 20 mA control outputs, supports EC ventilation fans and frequency inverters, and includes a two-line LC display for monitoring and measurement.
What safety precautions should be followed when using the A2G-100?
Always read the operating instructions before use, ensure the instrument is suitable for its intended application, and avoid use in hazardous areas. Follow all safety regulations and maintain the product label in a legible condition.
Who is considered skilled personnel for operating the A2G-100?
Skilled personnel must have the necessary qualifications, including knowledge of electrical systems, safety regulations, and country-specific standards. They should be trained to recognize and avoid potential hazards during operation.
What are the technical specifications of the A2G-100?
The A2G-100 operates on DC 24 V or AC 24 V ±10 % < 1 W, has a measuring range of -250 ... +250 Pa, and provides 0 ... 10 V or 4 ... 20 mA output signals. It is manufactured in the EU and includes a serial number for identification.
What should be done before installing the A2G-100?
Before installation, ensure that the operating instructions are read thoroughly, verify the scope of delivery against the delivery note, and confirm that the instrument is suitable for the intended application and environment.
What are the recommended storage conditions for the A2G-100?
The A2G-100 should be stored in a dry, cool place away from direct sunlight and extreme temperatures. Ensure that the instrument is protected from physical damage and kept in a secure location.
Can the A2G-100 be used in hazardous areas?
No, the A2G-100 is not permitted to be used in hazardous areas. It is designed and built solely for the intended use described in the operating instructions and must not be used in environments where there is a risk of explosion or fire.
What is the purpose of the LC display on the A2G-100?
The LC display on the A2G-100 simultaneously shows the direction of the monitoring output and the current measured value, allowing for real-time monitoring of the system's performance and ensuring accurate control.
How is the A2G-100 connected to the control system?
The A2G-100 connects directly to the EC ventilation fan or frequency inverter (FI) using a 0 ... 10 V or 4 ... 20 mA control output. The operator can adjust the output signals via a jumper within the instrument.