Product description:

The 3M 06972 is a respiratory protection device designed for use in environments with airborne contaminants. It features a disposable filter that effectively removes particulates, gases, and vapors. The mask is constructed from durable materials that ensure a secure and comfortable fit. It is suitable for a variety of industrial and occupational settings where respiratory protection is required. The design allows for easy breathing and provides a reliable level of filtration efficiency.

Frequently Asked Questions

How to assemble the respirator system?

To assemble the respirator system, first fit the pouch to the regulator as shown in Figure 1. Next, attach the breathing hose to the regulator as shown in Figure 2. Then, connect the breathing hose to the facepiece as shown in Figure 3. Ensure that the 3M logo on the < facepiece end of the breathing hose is facing up to ensure proper alignment of the breathing hose. If the system is to be used in the 6833/,(' $,5 02'( mode, attach a pair of 29(5)/2: 9$/9(6 0867 %( ),77(' to the breathing hose (see Figure 4). If the system is to be used in the '8$/ 02'( mode, attach a pair of &255(&(7 ),/7(56 0867 %( ),77(' to the breathing hose (see Figure 5). Connect the compressed air supply hose between the optional 3M Air Hose - Air Filter Unit and the S-200+ Regulator, ensuring the pressure at the Air Filter Unit is adjusted as described in the Technical Specifications section.

What should I check before using the respirator system?

Before using the respirator system, ensure that the equipment is complete, undamaged, and properly assembled. Any damaged or defective parts must be replaced with original 3M parts before use. Undergo pre-use checks on the facepiece as outlined in the appropriate user instructions. Make sure the cleaning channels are in place prior to use. Ensure that the filter coupling is fitted and replaced correctly after use.

How to adjust the airflow?

Adjust and secure the harness with the regulator comfortably around your waist. Adjust and fit the facepiece as outlined in the appropriate user instructions. Ensure at least minimum airflow into the facepiece is achieved and adjust the regulator airflow for maximum comfort.

What to do if airflow stops or decreases during use?

If airflow stops or decreases during use, immediately leave the contaminated area and investigate the cause. Take care to prevent the breathing hose from becoming entangled around protruding objects. If this occurs, leave the contaminated area and check the equipment is undamaged.

How often should filters be replaced?

Filters should be replaced regularly depending on the level of contaminant, work rate, exposure time, etc. Filters should be replaced when the wearer can detect breakthrough of the contaminant by touch or smell. Routine filter replacement before any contaminant is detected is highly recommended. Gas and vapor filters must be replaced as a pair even if no contaminant is detected within 1 week. If in doubt, always replace the filters with a new pair.

What are the markings on the regulator and hoses?

The S-200+ Regulator is marked to EN 14594 4% and EN 14594 3% and with a date of manufacture. The Compressed Air Supply Hoses are marked to EN 14594. They are also marked as follows: 308-00-403 is marked $ - suitable for use with Class $ devices (EN 14594). 308-00-723 is marked Heat Resistant and Anti-static.

What are the maintenance requirements for the system?

Maintenance, servicing, and repair must only be carried out by properly trained personnel. Use of unauthorized parts or unauthorized modifications could result in injury to life or health and may invalidate any warranty. This respirator is designed for minimal maintenance. If any components are damaged, they should be discarded and replaced. All replacement parts must be correctly installed.

What should I do if I detect an odor while using the system?

If an odor is detected while using the system, check the facepiece is properly fitted or damaged. Check the Air Hose Air Filter Unit requires maintenance if used. Check the external air supply quality for contamination.

How to properly don the respirator system?

To properly don the respirator system, adjust and secure the harness with the regulator comfortably around your waist. Adjust and fit the facepiece as outlined in the appropriate user instructions. Ensure at least minimum airflow into the facepiece is achieved and adjust the regulator airflow for maximum comfort.

How to properly doff the respirator system?

Do not remove the facepiece, filters, or, when in Supplied Air Mode, turn off the air supply until you have left the contaminated area. Remove the facepiece in accordance with the relevant user instructions. Disconnect the compressed air supply hose from the regulator. Unfasten the harness.