Log in


or


google Continue with Google

Already have an account?

Gesipa FireFox (122 pages)

0 out of 5
0 review

Tags

Loading...

Languages available:

No exact matches found. Please change your query

Loading...
Need help?

Need help?

Do you have a question about the product that is not answered in the manual?

  • Receive updates on solutions
  • Get answers to your question

Ask a question

Select image (Optional)

Product description:

The Riveting Machine Gesipa FireFox is a professional tool designed for high-performance riveting tasks. It features a robust construction and precise mechanics to ensure reliable and efficient operation. The machine is suitable for various applications in the automotive, aerospace, and construction industries. It offers adjustable rivet settings and a user-friendly design for ease of handling. The FireFox model is known for its durability and consistent performance under demanding working conditions.

Frequently Asked Questions

How to change the threaded mandrel?

To change the threaded mandrel, first disconnect the device from the compressed air supply. Loosen the counter nut with a double-ended wrench SW27, remove the mandrel tip with the counter nut, push the slider to the rear and hold it, unscrew the old mandrel, and screw in the new mandrel of the same size or appropriate thread size. Ensure the mandrel is securely locked in place using the internal hex of the slider. Adjust the mandrel length according to the nut size.

How to adjust the setting stroke?

To adjust the setting stroke, use the hex key SW4 to turn the adjustment screw until it is fully tightened. Press the green release button completely, then adjust the stroke using the stroke adjuster and scale. Each scale mark corresponds to 1 mm of stroke. Release the green button and ensure the stroke adjuster is locked. If the button does not lock automatically, carefully turn the adjuster until it is secured.

How to adjust the setting force?

To adjust the setting force, fully press the green release button, set the stroke to the maximum of 10 mm, and unscrew the adjustment screw until its front edge is approximately 10 mm from the device head. Drill the nut into the material, then press the trigger to start the setting process. If the nut is not deformed, tighten the adjustment screw by 1-2 turns. Repeat the process until the nut is sufficiently deformed. Tightening the screw increases the setting force, while loosening it reduces it.

How to wind down a nut?

To wind down a nut, place the blind rivet nut on the threaded mandrel without twisting. Press the nut firmly onto the mandrel in the direction of the device to start the winding process. Hold the nut in place until it contacts the mandrel tip. The winding process will automatically stop once the nut is in contact with the tip.

How to set a nut?

After winding the nut, insert it fully into the hole of the workpiece. Press and hold the trigger to start the setting process. The setting process will automatically stop once the set stroke or set force is reached. If the nut is not set properly, manually release the nut by pressing the release button or using the hex key to unscrew it.

How to manually remove a nut?

If the nut is not fully removed after a setting operation or if it was improperly positioned, manually remove it by pressing the release button. If the mandrel cannot be removed by pressing the button, use the hex key to unscrew it. Insert the hex key into the internal hex of the air motor and turn counterclockwise to loosen the mandrel.

How to maintain and care for the device?

Store the blind rivet nut gun in a dry location. Replace worn mandrels as needed. After prolonged use, refill or replace the hydraulic oil. To refill the oil, disconnect the device from the compressed air supply, remove the mandrel tip, set the stroke to 10 mm, and unscrew the oil refill screw. Fill the oil reservoir with hydraulic oil, and move the piston unit manually until oil flows freely. Reattach the oil refill screw and reconnect the device to the air supply.

Why is the nut not being wound down?

If the nut is not being wound down, possible causes include a defective nut thread, a defective mandrel, or the winding process not starting. Solutions include using a new nut, replacing the mandrel, or increasing the set stroke to the minimum required level.

Why is the nut not being removed?

If the nut is not being removed, possible causes include a deformed nut thread, a short drilling time, the nut not being automatically removed, the set stroke or force not being reached, or the nut being stuck on the mandrel. Solutions include reducing the set stroke or force, holding the trigger longer, refilling the hydraulic oil, or manually removing the nut using the release button or hex key.

Why is the set nut loose?

If the set nut is loose, possible causes include a too short set stroke, insufficient setting force, or low air pressure. Solutions include increasing the set stroke, increasing the setting force, or increasing the air pressure to 5-7 bar.

Send answer

Your opinion matters to us

Do you think we can improve or add something? Are there features missing or do you have suggestions for improvement? We would love to hear from you.

Give a rating

5 out of 5