Product description:

The Seca 634 is a high-precision digital scale designed for medical and clinical use. It features a large, easy-to-read display and a sturdy, durable construction. The scale is equipped with a weighing platform made of stainless steel, ensuring hygiene and long-term durability. It offers a weighing range of up to 150 kg with a precision of 100 g. The device is suitable for use in hospitals, clinics, and other healthcare facilities. It includes a calibration function for accurate measurements and is powered by a rechargeable battery, allowing for convenient use without the need for a power outlet.

Frequently Asked Questions

How to calibrate the seca 634 scale?

To calibrate the seca 634 scale, ensure the scale is on a stable, flat surface. Press the start button when the scale is unloaded. The display will show a sequence of numbers, followed by 0.0, indicating the scale is reset and ready for use.

How to switch between weight units on the seca 634?

To switch between weight units on the seca 634, press the kg/lbs/sts button. This will toggle between kilograms (kg), pounds (lbs), and stones (sts). Holding the button for approximately 2 seconds will switch between pounds and stones.

How to use the tara function on the seca 634?

To use the tara function, press the start button when the scale is unloaded. Place the additional weight (e.g., a chair) on the scale and press the HOLD/TARE button for a long duration. The display will reset to 0.0, and the tara function is activated. When the patient steps on, the scale will subtract the tara weight from the total weight.

How to use the pre-tara function on the seca 634?

To use the pre-tara function, press the start button when the scale is unloaded. Press the FUNC button to access the pre-tara function (FU 3). Select the desired storage location for the pre-tara weight. Adjust the value using the arrow keys, then press FUNC again to save. Place the chair on the scale, then the patient, and the scale will automatically subtract the pre-tara weight from the total.

How to calculate the body mass index (BMI) on the seca 634?

To calculate the BMI, press the start button when the scale is unloaded. Press the FUNC button to access the BMI function (FU 1). Use the arrow keys to select the storage location for the patient's height. Enter the height value, then press FUNC again to activate the BMI function. Step onto the scale, and the BMI will be displayed. Compare the result with the standard categories for adults.

How to adjust the damping on the seca 634?

To adjust the damping, press and hold the FUNC button for 2 seconds. The display will show FIL followed by the current damping setting: 0 = low damping (fast response), 1 = medium damping (normal response), 2 = high damping (slow response). Use the arrow keys to change the setting, then press FUNC again to save. The scale will return to normal operation.

What is the maximum weight capacity of the seca 634?

The seca 634 scale can handle a maximum weight of 360 kg (800 lbs). If the scale is overloaded, the display will show 'ST0P', indicating the weight exceeds the safe limit. Ensure the patient's weight does not exceed this capacity to avoid damage to the scale.

How to turn off the seca 634 scale?

To turn off the seca 634 scale, press the start button again after use. The scale will automatically power down. If the scale is in battery mode, it will turn off after 5 minutes of inactivity. If connected to power, it will only turn off via the start button.

How to store multiple weight values on the seca 634?

The seca 634 allows you to store up to three different weight values (e.g., for different chairs). To store a weight, press the start button when the scale is unloaded. Press FUNC to access the storage function, select the desired storage location, and adjust the weight value using the arrow keys. Press FUNC again to save the value.

What are the safety precautions for using the seca 634?

Before using the seca 634, ensure the scale is placed on a stable, flat surface. Avoid dropping the scale or exposing it to heavy impacts. Keep the power cable securely routed to prevent tripping hazards. Regular maintenance is recommended to ensure safe and accurate operation. Do not use the scale in environments with excessive moisture or dust.