What is the maximum detection range of the VE1016 detector?
The VE1016 detector has a maximum detection range of 16 meters (52 feet 6 inches).
How do you set the DIP switch for the AM/TF output?
To set the DIP switch for the AM/TF output, use switch SW4. Set it to 'On' to signal AM on both the AM and Alarm relays, and TF only on the AM relay (EN 50131). Set it to 'Off' for the factory default, which signals AM and TF on the AM relay.
What are the recommended installation distances to avoid false alarms?
Avoid installing the detector within 50 cm (20 inches) of objects that may cause false alarms. Also, ensure no objects are within 1 meter of the detector for 60 seconds after power-up to prevent false AM alarms.
What is the operating temperature range for the VE1016 detector?
The VE1016 detector operates within a temperature range of -10°C to +55°C (+14°F to +130°F).
How do you configure the detection pattern?
To configure the detection pattern, remove the blinders and adjust the curtain fragments as needed. For a 90° coverage, use the SB01 swivel-mount bracket. Ensure the mirror stickers are correctly placed for optimal performance.
What is the power supply requirement for the VE1016 detector?
The VE1016 detector requires a power supply of 9 to 15 VDC (12 V nominal).
What is the startup time for the VE1016 detector?
The VE1016 detector has a startup time of 25 seconds. During this time, the AM circuitry calibrates itself to its environment.
What are the LED indications for the VE1016 detector?
The VE1016 detector has two LEDs: a red LED for PIR intruder alarm and a yellow LED for AM/TF status. The red LED is continuously on during normal operation and blinks rapidly during an alarm. The yellow LED blinks normally (1 Hz) or rapidly (4 Hz) depending on the system status.
What are the jumper settings for the VE1016 detector?
The jumper settings for the VE1016 detector include J1 (not used), J2 (PIR LED control), J3 and J4 (dual loop setting), and J5 (D/N or Rtest mode). J6 controls the polarity of the control voltage (CV).
What are the dimensions of the VE1016 detector?
The VE1016 detector has dimensions of 108 mm (height) x 60 mm (width) x 46 mm (depth), or 4.25 inches x 2.36 inches x 1.81 inches.
Related products from Aritech
EV666
User manual 8 pages
VE1120AM-D
User manual 10 pages
DC138R4.7
User manual 10 pages
DP721RTA
User manual 32 pages
EV669
User manual 20 pages
EV666-D
User manual 20 pages
VE1012
User manual 20 pages
VE1012AM
User manual 20 pages
ATS1235
User manual 22 pages
VE1016 Serie
User manual 28 pages
700 Serie
User manual 32 pages
DP721T
User manual 32 pages
DP721I
User manual 32 pages
DP721R
User manual 32 pages
DT713-5
User manual 32 pages
DT713-5R
User manual 32 pages
DP721RT
User manual 32 pages
DT713-7
User manual 32 pages
EV1116AM
User manual 38 pages
EV1012 Serie
User manual 40 pages