Dräger X-plore 4740 (95 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
How to properly fit the half mask with head straps?
To fit the half mask with head straps, first loosen the harness by pulling the ends as far as possible towards the head straps. Then push the half mask up to the head straps and close the locking hooks. Fit the mask over your mouth and nose, pull the head straps over your head, and position them on the back of your head. Finally, pull the ends of the harness until the mask sits tightly on your face.
How to fit the half mask with a headband?
To fit the half mask with a headband, lift the lug with your thumb and pull the headband as far as possible in the direction of the arrow. Fit the mask over your mouth and nose, position the headband on the back of your head, and guide the harness over your ears. Pull the ends of the headband until the mask sits tightly on your face.
What are the conditions for using the half mask?
The oxygen content in the ambient air must not drop below 17 vol. % in Europe (except Netherlands, Belgium, UK) or 19 vol. % in the Netherlands, Belgium, UK, Australia, and New Zealand. Avoid entering unventilated tanks, pits, canals, etc. with filter equipment. Ensure you know the types of contaminants and wear appropriate eye and head protection. Select a respiratory filter with a weight not exceeding 300 g and follow its instructions.
What types of respiratory filters can be used with the half mask?
The half mask can be used with particle filters, gas filters, or combined filters that are approved according to EN 14387:2004 and EN 143:2000 or AS/NZS 1416. Alternatively, it can be connected to purifying respirators like X-plore 7300, X-plore 7500, and Panorama BelAir GC, or compressed air hose units like Abil-R and X-plore 9000.
How to check if the half mask is leak-tight?
To check if the half mask is leak-tight, seal the filter connection with your hand and inhale until negative pressure is generated. Hold your breath for a moment. If the mask does not maintain the negative pressure, retighten the straps or use a different mask size. This test should be done before each use and after any maintenance or replacement of parts.
What should I do after using the half mask?
After using the half mask, disinfect it by placing all parts into a disinfectant bath, rinsing with clean water, and drying at a maximum temperature of 60°C. If using a headband, loosen it and remove the mask. Ensure the mask is thoroughly cleaned and disinfected to prevent contamination and maintain its effectiveness.
How to clean the half mask?
Clean the half mask immediately after use with lukewarm water and an all-purpose detergent like Sekusept Cleaner or Eltra. Rinse thoroughly with clean water and dry at a maximum temperature of 60°C. Avoid using organic solvents such as acetone, alcohol, or benzene, as they can damage the mask and reduce its sealing effectiveness.
What are the maintenance intervals for the half mask?
The half mask should be inspected and cleaned regularly. Check for cracks, brittleness, or deformations in all parts. Replace the exhalation valve disc if it is damaged or contaminated. The half mask should be checked for airtightness with a testing device like Dräger Prestor after each cleaning or part replacement. Follow the manufacturer's guidelines for regular maintenance and inspection.
How to disinfect a silicone mask?
Silicone masks are prone to absorbing cleaning and disinfecting agents, so use only approved products and limit exposure time to a minimum. After cleaning and disinfection, rinse each part thoroughly for 10 minutes under running water. Avoid prolonged contact with disinfectants to prevent skin irritation and ensure the mask remains effective.
What should I do if the half mask is not sealing properly?
If the half mask is not sealing properly, check the sealing profile and ensure it is correctly seated in the adaptor. If the mask is not leak-tight, it can lead to intoxication. Retighten the straps or use a different mask size. If the issue persists, consult a qualified professional to inspect and replace damaged parts.
Related products from Dräger
PARAT C
User manual 2 pages
PARAT C
User manual 100 pages
PARAT 4500
User manual 2 pages
PSS BG 4 plus
User manual 162 pages
X-plore 1700
User manual 2 pages
X-plore 6000
User manual 2 pages
X-plore 6000
User manual 86 pages
X-plore 6000
User manual 90 pages
X-plore 6000
User manual 118 pages
X-plore 6000
User manual 214 pages
X-plore 8000
User manual 26 pages
X-plore 8000
User manual 46 pages
X-plore 8000
User manual 50 pages
X-plore 8000
User manual 64 pages
X-plore 8000
User manual 74 pages
X-plore 8000
User manual 202 pages
X-plore 8000
User manual 206 pages
X-plore 3500
User manual 3 pages
X-plore 3500
User manual 6 pages
X-plore 3500
User manual 172 pages