Product description:
Frequently Asked Questions
How do SB Series AIR Beam Detectors work?
The SB Series AIR Beam Detectors use pulsed infrared beams to create a non-physical detection zone. They generate an alarm when one or two beams are interrupted, ignoring small animals, birds, or dead leaves. These detectors operate on four user-selectable frequencies to avoid interference between units.
What are the maximum outdoor ranges for the detectors?
The maximum outdoor ranges vary by model: SB250-N and SB2100-N have a range of 50 m and 100 m respectively, while SB450-N and SB4100-N have a range of 50 m and 100 m. The SB4200-N has a maximum range of 200 m. The range depends on visibility conditions, with a maximum range of 200 m when visibility is 200 m.
How many cells do the detectors have?
The SB250-N and SB2100-N detectors have one cell each, while the SB450-N, SB4100-N, and SB4200-N detectors have two cells, forming a dual-beam configuration. This allows for more accurate detection and reduced false alarms.
What are the operating modes for the SB450-N and SB4100-N detectors?
The SB450-N and SB4100-N detectors have two operating modes: 'AND' mode, which triggers an alarm when both adjacent cells are obstructed, and 'OR' mode, which triggers an alarm when any one cell is obstructed. These modes allow for different installation scenarios.
How do you mount the detectors on a wall?
To mount the detectors on a wall, use appropriate screws and wall plugs for the type of wall. Drill four holes and insert wall plugs, then position the holes in the adjustable support over the wall plugs. Ensure the module is rotated to access the screw holes in the adjustable support.
How do you remove the infrared cover?
To remove the infrared cover, first unscrew the attachment screw, taking care not to lose the staple. Slide the cover upwards until it is stopped by the top plate, then pull it outwards from the grooves in the chassis to remove it.
What are the DIP switch settings for channel selection?
The DIP switches allow you to select the operating channel for the detector. Switch 1 and Switch 2 determine the channel: OFF/OFF for Channel 1, ON/OFF for Channel 2, OFF/ON for Channel 3, and ON/ON for Channel 4. Refer to the 'Channel selection' section for more details.
How do you set the operating mode for the detectors?
The DIP switches 3 to 5 are used to set the operating mode. For example, OFF/OFF/ON sets the module to 'AND' mode, while OFF/OFF/OFF sets it to 'OR' mode. Other combinations set the module to 'Slave' or 'Master' mode with specific detection settings.
What is the purpose of the alarm LED?
The alarm LED indicates intrusion alarms or disqualification status. It blinks when an intrusion alarm is triggered and shows the signal level during alignment. This helps in verifying the system's status and ensuring proper operation.
How do you connect the tamper detection contact?
The tamper detection contact is connected to the terminal block. This allows the system to detect any unauthorized tampering with the detector. Ensure the contact is properly connected to maintain system security and functionality.