How to safely disconnect power before working on the sensor?
Before performing any work on the sensor, ensure the power supply is disconnected. Verify the absence of voltage using a voltage tester.
What should be done before installing the sensor?
Before installing the sensor, ensure the connected electrical wiring is de-energized. Turn off the power and verify the absence of voltage with a voltage tester.
What type of wiring is required for the sensor installation?
The wiring must comply with VDE 0100 standards. For BLS D and BLS DF models, a multi-core cable containing both the mains and control wires (e.g., NYM 5 x 1.52) can be used between the sensor and the EVG.
What is the maximum power rating for the sensor?
The sensor can handle a maximum power rating of 2000 W for resistive loads, 1000 W for NV-halogen lamps, and 1000 W for fluorescent lamps with KVGs (cos φ = 0.5).
What is the recommended mounting height for the sensor?
The recommended mounting height for the sensor is between 2.5 to 3 meters when installed on the ceiling.
What is the detection range of the sensor?
The sensor has a 360° horizontal and 180° vertical detection range. It can detect movement within a safe distance of up to 12 meters for walking people and 2 meters for sitting individuals.
How does the sensor adjust the lighting based on ambient light?
The sensor continuously measures ambient light and compares it to the set brightness level. If the ambient light is below the set level, motion triggers the lighting. The sensor adjusts the brightness accordingly to maintain consistent illumination.
How to adjust the brightness level on the sensor?
Use the potentiometer on the sensor to adjust the brightness level. This setting determines the minimum ambient light level at which the sensor will activate the lighting.
How to reset the brightness level to its default setting?
To reset the brightness level to its factory default, press both the (+) and (−) buttons simultaneously. This action will revert the brightness level to the original setting.
What is the delay time for turning off the light after detecting no motion?
The delay time for turning off the light after detecting no motion ranges from 4 to 30 minutes, or up to 2 hours, depending on the model and settings.
Related products from STEINEL
iHF 3D KNX V3.5
User manual 39 pages
IS 2180-5
User manual 72 pages
IS 2180-5
User manual 72 pages
IS 3180 DALI
User manual 78 pages
IS 3180 DALI
User manual 78 pages
IS 345 DALI
User manual 78 pages
IS 345 DALI
User manual 78 pages
IS 3360 DALI
User manual 78 pages
IS 3360 DALI
User manual 78 pages
PD-24 ECO KNX
User manual 772 pages
PD IR 4360-24 KNX
User manual 772 pages
PD IR 4360-8 KNX
User manual 772 pages
PD-8 ECO KNX
User manual 772 pages