Log in


or


google Continue with Google

Already have an account?

Eaton FT1SU400CGSIP (4 pages)

0 out of 5
0 review

Tags

Loading...

Languages available:

No exact matches found. Please change your query

PDF page 1
Loading...
Need help?

Need help?

Do you have a question about the product that is not answered in the manual?

  • Receive updates on solutions
  • Get answers to your question

Ask a question

Select image (Optional)

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Product description:

The Eaton FT1SU400CGSIP is a molded case circuit breaker designed for safety technology applications, with a rated current of 400 amperes. It provides reliable protection against overcurrents, short circuits, and potential ground faults through its thermal-magnetic trip mechanism, ensuring precise fault detection and interruption. The device features a compact, robust construction suitable for industrial environments, with options for adjustable settings to enhance system adaptability. It supports standard mounting configurations and complies with relevant electrical safety standards, helping to safeguard personnel and equipment from electrical hazards. This model is engineered for durability and ease of integration into power distribution systems.

Frequently Asked Questions

What is the rated current and primary use of the Eaton FT1SU400CGSIP?

The FT1SU400CGSIP is rated for 400 amperes and is designed for safety-technology and industrial power distribution applications. It provides reliable overcurrent and short-circuit protection, helping safeguard personnel and equipment while enabling predictable system coordination and planning.

How does the thermal-magnetic trip mechanism protect electrical systems?

The thermal-magnetic mechanism combines a thermal element for time-delayed overload protection and a magnetic element for fast response to short circuits. This ensures both gradual overloads and instantaneous faults are interrupted, improving safety and reducing equipment stress when properly coordinated.

How does the breaker respond to ground-fault currents or earth leakage?

The FT1SU400CGSIP will interrupt ground-fault currents if those currents produce an overcurrent condition detectable by its thermal-magnetic trip. It is not a dedicated residual-current device, so dedicated earth-leakage protection should be used where selective ground-fault detection or personnel protection is required.

What installation and mounting options does the FT1SU400CGSIP support?

This model supports standard industrial mounting configurations suitable for panelboards and switchgear. Its compact, robust construction allows straightforward integration, but installers should confirm physical dimensions, bus compatibility and correct torque values during installation for secure connections.

Are there adjustable trip settings on the FT1SU400CGSIP and why use them?

The breaker offers adjustable settings or accessory options that allow tuning of long-time and short-time responses. These adjustments enable better selectivity and coordination within a distribution system, reducing nuisance trips while maintaining protective performance when configured properly.

What environmental and durability features make it suitable for industrial use?

The breaker is engineered with a robust molded case and construction aimed at industrial environments, offering mechanical durability and stable electrical performance. For longest service life, install in appropriate enclosures and avoid corrosive atmospheres, excessive moisture, or prolonged high-temperature exposure.

How should I size conductors and upstream/downstream protection for a 400 A breaker?

Select conductors with ampacity equal to or exceeding the breaker's 400 A rating while accounting for derating factors, ambient temperature and conduit fill. Coordinate upstream and downstream protective devices for selective fault clearing and verify compatibility with bus and lug ratings.

What routine maintenance and inspection practices are recommended for this breaker?

Recommend scheduled visual inspections, torque checks on terminals, contact condition assessment, and periodic functional testing of the trip mechanism. Thermal imaging to detect hot connections and keeping contacts clean extends service life and reduces the risk of unexpected failures.

How does the FT1SU400CGSIP contribute to personnel and equipment safety?

By reliably detecting and interrupting overloads and short circuits within its rated limits, the breaker minimizes fire risk and equipment damage. Properly coordinated protection helps isolate faults quickly, protecting personnel and reducing downtime in industrial electrical systems.

Can the FT1SU400CGSIP be integrated into an existing power distribution system?

Yes, it is designed for ease of integration into common power-distribution configurations. Verify mechanical fit, mounting, busbar and conductor compatibility, and perform coordination studies to confirm the breaker’s trip characteristics match system protection requirements.

Send answer

Your opinion matters to us

Do you think we can improve or add something? Are there features missing or do you have suggestions for improvement? We would love to hear from you.

Give a rating

5 out of 5
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.