IKAR HRA (76 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the maximum lifting capacity of the HRA device?
The maximum lifting capacity of the HRA device is 136 kg, which ensures safe operation during rescue scenarios.
What standards does the HRA device comply with?
The HRA device complies with EN 360:2002, EN 1496:2017 B, and ANSI/ASSE Z359.14-2014, ensuring compliance with international safety standards.
How often should the HRA device be inspected?
The HRA device must be inspected at least once every twelve months by authorized personnel to ensure continued safe operation.
What is the purpose of the rescue mechanism?
The rescue mechanism allows for the safe retrieval of an injured person by lifting them using the hand crank, ensuring their safety during emergencies.
What should be done if the device shows signs of damage?
If the device shows signs of damage, such as a broken or frayed cable, it must not be used and should be immediately removed from service until it is inspected and approved by a qualified technician.
What are the requirements for anchoring the HRA device?
The HRA device must be anchored to a secure and suitable attachment point with a minimum load capacity of 9 kN (22.2 kN in North America), using approved connectors and following EN 362:2004 and ANSI/ASSE Z359.12-2009 standards.
Can the HRA device be used in extreme temperatures?
The HRA device is designed for use in temperatures ranging from -40°C to +50°C, making it suitable for a wide range of environmental conditions.
What should be done if the device is exposed to corrosive substances?
The HRA device should be protected from exposure to welding flames, sparks, fire, acids, alkalis, solvents, and similar substances to maintain its integrity and functionality.
How should the cable be maintained?
The cable should be wound under load only, and it must never be fully retracted and released, as this can cause damage to the return spring. Regular cleaning with acid-free oil or Vaseline is recommended for devices exposed to weather.
What is the recommended procedure after using the rescue function?
After using the rescue function, the device must be inspected by a qualified technician trained by the manufacturer to ensure it remains safe for future use.