SICK LE20 (690 pages)
Tags
Languages available:
No exact matches found. Please change your query
Need help?
Do you have a question about the product that is not answered in the manual?
- Receive updates on solutions
- Get answers to your question
Product description:
Frequently Asked Questions
What is the purpose of the LE 20 safety evaluation unit?
The LE 20 safety evaluation unit is designed to ensure the safe operation of light curtains by periodically checking their secure function according to category 2 requirements. It connects machine control to light curtains, stops dangerous movement in case of a fault, and provides additional safety and monitoring functions to the light curtain system.
What are the safety requirements for using the LE 20?
The LE 20 must be used in conjunction with specific safety light curtains such as C 2000, M 2000, or testable single-beam light curtains. It must be installed and operated according to national and international regulations, including the Machinery Directive and safety standards. All safety requirements must be verified through proper testing and documentation.
How should the LE 20 be installed to ensure safety?
The LE 20 must be installed with the reset and override buttons positioned so they cannot be activated from the danger zone. The entire danger zone must be visible from these buttons. The external power supply must meet EN 60204 standards to handle short power outages. The system must also be tested to confirm compliance with safety regulations.
What are the requirements for the Muting function?
Muting must be activated only when an object blocks access to the danger zone. It must not rely solely on electrical signals or software and must be automatically deactivated once the object has passed. A muting indicator light is required to show increased safety risk during muting. The entire danger zone must remain visible from the reset and override buttons.
How should light curtains be positioned with the LE 20?
Light curtains must be positioned so that any interruption of a light beam only triggers the safety function after the dangerous condition has been resolved. This requires adherence to safety distances as specified in EN 999. The light curtains must also be installed to prevent any bypassing or circumvention of the light beams.
What are the requirements for single-beam light curtains with the LE 20?
Single-beam light curtains can only be used as access protection according to EN 999. They cannot be used for finger or hand protection. Interference from external light sources, such as sunlight or remote controls, must be prevented. The number of beams and distances between them must match, and sensor angles must be carefully managed to avoid mutual interference.
What should be done if the light curtain sensors are dirty or damaged?
If the light curtain sensors or their emitting/receiving surfaces are dirty or damaged, they must be cleaned or replaced immediately. This ensures the light curtain system continues to function correctly and maintains its safety integrity.
What are the requirements for the installation of the LE 20 with C 2000 or M 2000?
The installation of the LE 20 with C 2000 or M 2000 must follow the technical specifications for these devices. The system must be installed without obstructing the optical beam path, and the installation must be planned according to the technical documentation provided by SICK.
How should reflective surfaces be handled with the LE 20?
Reflective surfaces within the sending and receiving beam paths must be positioned or removed to prevent objects or people from being misidentified. All reflective surfaces and objects must maintain a minimum distance from the optical axis between the sender and receiver to avoid optical interference.
What are the key safety functions of the LE 20?
The LE 20 includes several safety functions such as the restart lock (RES), which prevents unintended restarts, and the emergency stop function (EDM), which ensures the system stops in case of a fault. It also supports muting operations, which allow temporary disabling of the safety function under controlled conditions, provided all safety requirements are met.