Frequently Asked Questions
What is the maximum temperature for U48X?
The maximum temperature for U48X is 60°C. At this temperature, the recommended length is 1 meter. For higher temperatures, the length decreases accordingly.
What is the recommended length for U23X at 40°C?
For U23X at 40°C, the recommended length is 1.5 meters. This ensures optimal performance and safety under these conditions.
How does temperature affect the length of the installation?
Temperature directly affects the required length of the installation. For example, at 40°C, the length is 1.5 meters, while at 60°C, it reduces to 1 meter, and at 90°C, it further shortens to 0.5 meters.
What is the torque requirement for the installation?
The torque requirement for installation is between 10 and 20 Nm. This range ensures proper tightening without over-stressing the components.
What is the formula for calculating the expansion gap (e)?
The expansion gap (e) is calculated using the formula ∆T (°C) = T max. - T inst. For each 10°C difference, the expansion gap increases by 5 mm, up to a maximum of 11 mm for a 50°C difference.
What are the recommended dimensions for the installation?
The recommended dimensions include a height (h) of 60 mm or 60/100 mm, and a length (L) that varies based on temperature. For example, at 40°C, the length is 1.5 meters, and at 60°C, it is 1 meter.
What are the part numbers for the installation components?
The part numbers for installation components include 66809, 66809-48, 66819, 66829-A2, 66829-A4, and 66839-A2, among others. These are used for different parts of the installation process.
What is the maximum length for U48X at 40°C?
The maximum length for U48X at 40°C is 1.5 meters. This length is specified to ensure proper thermal expansion and mechanical stability under these conditions.
What is the recommended torque for the installation bolts?
The recommended torque for installation bolts is between 10 and 20 Nm. This range ensures secure fastening without causing damage to the components.
What is the purpose of the expansion gap in the installation?
The expansion gap is designed to accommodate thermal expansion and contraction of the material during operation. This prevents stress buildup and potential damage to the installation.